Power Terminal - Dimplex ASCARI MA12 Installation Manual

Electric heating boiler
Hide thumbs Also See for ASCARI MA12:
Table of Contents

Advertisement

2.14 - Power terminal

Put the self-sealing nut (supplied with the boiler) for
connection to mains from the bottom of the casing.
5 self-sealing nuts for accessories connections
(Ambience thermostat, outside and/or Domestic Hot
Water sensor and remote cut-out)
Connections are cage-clamp terminals, to be used as to follow :
- For accessories terminals use a 2,5 x 0,4mm blade screwdriver
- For power terminal use a 3,5 x 0,5mm or 5,5 x 0,8mm blade
screwdriver.
1 : Introduce the blade of the driver into the opening located just
above or bellow the mark with a slight pivoting move to center.
2 : Introduce the connector's terminal inside the cage.
3 : Remove the screwdriver
Put the self-sealing nut (supplied with the boiler) for
connection to mains from the top of the casing. In
this case remove the plastic cap and close the hole
below casing using same.
or
Screw A
Ascari MA12 -p. 22 -
Plastic cap moved from top
to bottom

Hide quick links: