MOUNTING THE TANK
STEP
A
16" or less from
faucet base
and
30" or less
from standard
grounded outlet
B
leave 1/4"
exposed
C
Hang tank and
tighten screws
DO NOT extend plumbing
or electrical lines
CONNECTING FAUCET TO TANK
STEP
A
Tank
must be
mounted
level.
FINAL WATER CONNECTION
STEP
A
Brass Nut
copper
1/4" tube
with only
1/2 turn
clockwise.
Press ALL tubes in once again to ensure secure fit.
Electric Shock Hazard:
can result in serious injury or death from electric shock. Improper connection of the equipment
grounding conductor can result in the risk of shock by electricity.
blue
white
clear
tube
tube
tube
1
2
3
B
Ferrule
copper
1/4" tube
This appliance MUST be grounded. Using an ungrounded appliance
For Technical Assistance
1-800-845-8345
FILL TANK & THEN CONNECT POWER
STEP
A
Run the water for at least 2 minutes to flush lines.
B
DO NOT plug in unit until
water flows from faucet

Advertisement