Features Menu - Directed Electronics 561T Installation Manual

Hide thumbs Also See for 561T:
Table of Contents

Advertisement

features menu

The factory default settings are indicated in bold text in the table below.
FEATURE
DEFAULT - LED ON SETTING
NUMBER
(PRESS CHANNEL 1)
1
Engine checking on
2
Tachometer checking type
3
12 minutes run time (1)*
4
Flashing parking light output
5
Cranking time 0.6 sec. (1)
6
Voltage check high level
7
No function
8
Activation pulse: 1 (1)
9
Ignition/accessory output: Ignition
10
Accessory state during wait to start: OFF
2 nd status output: Normal
11
12
No function
13
No function
14
No function
*NOTE: The number in parentheses indicate the number of times the LED will flash
© 2003 Directed Electronics, Inc. Vista, CA
LED OFF SETTING
(PRESS CHANNEL 2)
Engine checking off
Voltage checking type
24 minutes (2)*, 60 minutes (3) run time
Constant parking light output
Cranking time 0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5),
1.6 (6), 1.8 (7), 2.0 (8), 4.0 (9) sec.
Voltage check low level
Activation pulses: 2 (2), 3 (3)
Ignition/accessory output: Accessory
Accessory state during wait to start: ON
Rear defogger latched/pulsed
27

Hide quick links:

Advertisement

Table of Contents
loading