Lincoln Electric REDI-MIG Plus 215C Operator's Manual page 4

Table of Contents

Advertisement

CYLINDER may explode if
damaged
5. a. U se only compressed gas cylinders containing
the correct shielding gas for the process used and
properly operating regulators, designed for the gas
and pressure used. All hoses, fittings, etc. should be
suitable for the application and maintained in good
condition.
b. A lways keep cylinders in an upright position and
securely chained to an undercarriage or fixed
support.
c. Cylinders should be located :
A way from areas where they may be struck or
subjected to physical damage.
A safe distance from arc welding or cutting
operations and any other source of heat, sparks
or flame.
d. N ever allow the electrode, electrode holder, or any
other electrically "hot" parts to touch a cylinder.
e. K eep your head and face away from the cylinder valve
outlet when opening the cylinder valve.
f. V alve protection caps should always be in place
and hand-tight except when the cylinder is in use or
connected for use.
g. R ead and follow the instructions on compressed gas
cylinders and associated equipment, and AS 2030
Parts 1 & 2.
FOR ELECTRICALLY
powered equipment
6. a. T urn off input power using the disconnect switch at the
fuse box before working on the equipment.
b. I nstall equipment in accordance with the SAA Wiring
Rules, all local codes and the manufacturer's recom-
mendations.
c. E arth the equipment in accordance with the SAA
Wiring Rules and the manufacturer's recommenda-
tions.
HAVE ALL INSTALLATIONS, OPERATION, MAINTENANCE AND REPAIR WORK PERFORMED BY QUALIFIED PEOPLE
For more detailed information it is strongly recommended that you purchase a copy of "Safety in Welding and Cutting - ANSI Standard Z
49.1" and WTIA Technical Note 7. All WTIA publications and ANSI/AWS Standards are available from the Welding Technology Institute of
Australia, P.O. Box 6165, Silverwater NSW 2128. For copies of various Australian Standards contact your local S.A.A. office.
For more detailed information it is strongly recommended that you review copies of "Safety in Welding and Allied processes - AS 1674.1 &
.2" and WTIA Technical Note 7 – TN07. Australian Standards are available from SAI Global – www.saiglobal.com and WTIA publications
are available from the Welding Technology Institute of Australia – www.wtia.com.au.
To ensure that you receive the correct replacement part the following procedure should be followed:
1. Quote Serial Number and Code Number.
2. Q uote the Description, Item Number and Parts List Number of the desired part. When ordering parts for items carrying brand
names of other companies, such as fan motors, drive shafts, etc., be sure to include the other company's name and part number
and other relevant information.
3. Should the primary cord be damaged, a special cord is required, and is available from Lincoln Electric.
4. P arts should be ordered from Lincoln, its offices or the nearest Authorised Field Service Shop. (The "Lincoln Service Directory"
listing these shops geographically is available on request.)
Note: "Hardware" in the Lincoln Parts Lists are not Lincoln stock items but can be obtained via the Field Service Shop network.
Component parts of assemblies such as stator coils or armature coils, etc., which require electrical testing or locating fixtures are
not considered replaceable items. This is to ensure that the customer receives parts which will keep the welder in the best operating
condition.
Page 4
7.
HOW TO ORDER REPLACEMENT PARTS
BUY ONLY GENUINE REPAIR PARTS
REDI-MIG
Plus 215C, 255C, 255S
®
FOR ENGINE
powered equipment
a. T urn the engine off before troubleshoot-
ing and maintenance work unless the
maintenance work requires it to be
running.
b. O perate engines in open, well ventilated
areas or vent the engine exhaust fumes
outdoors.
c. D o not add fuel near an open flame,welding
arc or when the engine is running. Stop the
engine and allow it to cool before refuelling
to prevent spilled fuel from vaporizing on
contact with hot engine parts and igniting.
Do not spill fuel when filling tank. If fuel is
spilled, wipe it up and do not start engine
until fumes have been eliminated.
d. K eep all equipment, safety guards, covers
and devices in position and in good repair.
Keep hands, hair, clothing and tools away
from V-belts, gears, fans and all other
moving parts when starting, operating or
repairing equipment.
e. I n some cases it may be necessary to
remove safety guards to perform required
maintenance. Remove guards only when
necessary and replace them when the
maintenance requiring their removal is
complete. Always use the greatest care
when working near moving parts.
f. D o not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
g. T o prevent accidentally starting petrol
engines while turning the engine or welding
generator during maintenance work,
disconnect the spark plug wires, distributor
cap or magneto wire as appropriate.
h. T o avoid scalding do not remove the
radiator pressure cap when the engine is
hot.
IM6016

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Redi-mig plus 255sRedi-mig plus 255c

Table of Contents