Platform
Metal
Safety Strips
Figure 8
*
Metal
Safety Strips
*
Figure 9
The safety strips should extend in front and
sides of the fireplace opening 2" (51 mm) . In
the event a wooden support is used to elevate
the fireplace above the floor, a "Z" type safety
strip should be fabricated and used to protect
the front surface of the wood support as well
as the floor beneath the hearth extension ( see
Figures 8 and 9 ). The safety strips should be
tacked down to prevent possible movement.
Note: The "Z" type safety strip is not supplied.
Step 3. Refer to fireplace drawings and speci-
fications on pages 7 and 8 for framing dimen-
sions and details. False header may be posi-
tioned directly on top of the fireplace spacers
( see Figures 10, 11 and 12 ).
6
IMPORTANT: UNDER NO CIRCUMSTANCES
CAN THE FIREPLACE TOP SPACERS ( FIGURE
10 ) BE REMOVED OR MODIFIED, NOR MAY
YOU NOTCH THE HEADER TO FIT AROUND
OR BE INSTALLED LOWER THAN THE SPAC-
ERS. THE HEADER MAY BE IN DIRECT CON-
TACT WITH THE TOP SPACERS BUT MAY NOT
BE SUPPORTED BY THEM.
4 x 6 Header
2" Min.
(51 mm)
2 x 4 False
Header
Spacer
*
2" Min.
Figure 10
(51 mm)
Figure 11
Figure 12
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

FRAMING WALL VARIATIONS

As many as six (6) different framed wall con-
figurations can be constructed to enclose the
LS43ST fireplace. The following illustrations
depict these variations of wall enclosures. Sev-
eral of these designs may incorporate book
shelves, wood storage boxes, etc.
No Combustible
Materials in
Shaded Areas
Note: A minimum 2"
air space clearance
to combustibles and
any portion of the
chimney is required.
No Combustible
Materials in
Shaded Areas
Figure 13
LS43ST - Wall Types
"C" Type Wall
"T" Type Wall
"L" Type Wall
"H" Type Wall
"Y" Type Wall
Parallel Wall