Troubleshooting Guide

Operation
Troubleshooting Guide
Problem/Symptom
Possible Causes
Solution
Low output voltage
Overload
Reduce the load.
No output voltage
Low input voltage
Recharge battery.
Check connections
and cable.
No output voltage
Thermal
Allow inverter
after prolonged use
shutdown
to cool off.
Reduce load,
continuous
operation input
current required.
Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed.
Reduce ambient
temperature.
No output voltage,
High input
Make sure
"Protect" indicator
voltage
the inverter is
connected to
lighted
12V battery.
Check regulation
of charging system.
No output voltage
Short circuit
Check load for
proper operation.
No output voltage
Inverter
Turn inverter on.
switched off
No power
Check wiring
to inverter
to inverter.
Reverse
Observe
DC polarity
correct polarity.
Low battery alarm
Poor DC wiring
Check
on all the time
connections.
Poor battery
Make sure battery
condition
is fully charged.
14

Specifications

Operation
Specifications
Continuous output power (1 hour) . . . . . . . . . . . . 800W
Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . 1600W
Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88%
Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83%
No load current draw . . . . . . . . . . . . . . . < 0.5A (12.6V)
Output waveform (resistive load) . . . Modified sine wave
Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ
Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V
USB output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V
Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC
Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V
Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V
Operating temperature range . . . . . . . . . . . . 0°C – 40°C
Storage temperature range . . . . . . . . . . . . -40°C – 85°C
Protection . . . . . . . . . .Overload, short-circuit, overtemp,
reverse polarity, under/over voltage
Notes
All protection is automatically recovered.
To protect the battery, if the unit needs to be restarted
after low voltage protection, the voltage of DC input
should be above 12V.
To extend the life of the fan, it will stop when there is no
load. The speed of the fan increases as the load increases.
The unit is completely insulated in input and output for
added safety.
Nothing Comes Close to a Cobra
(32°F – 104°F)
(-40°F – 185°F)
®