Operating Limits

Operation
Intro
Operation
Customer
Operating Limits

Assistance

Power Output
The inverter can deliver 1500 watts for about 60 minutes .
The inverter must cool for 15 minutes before it can resume
Installation
operation at 1500 watts . Note: The wattage
rating applies to resistive loads .
Secondary Icons
The inverter will operate most AC loads within its power
rating . Some induction motors used in freezers, pumps, and
other motor-operated equipment require very high surge
currents to start . The inverter may not be able
Notice
Caution
to start some of these motors even though their rated
current draw is within the inverter's limits . The inverter
will normally start single phase induction motors rated
at one-half HP or less .
Input Voltage
The inverter will operate from input voltage ranging
from 10 volts to 15 volts . Optimum performance will
occur when the voltage is between 12 volts and 14 volts .
If the voltage drops below 11 .3V+/-0 .3V, an audible low
battery warning will sound . The inverter will shut down if
the input voltage drops below 10 .3V+/- 0 .3V . This protects
the battery from being over-discharged . It will restart
when the input voltage exceeds 12V+/- 0 .3V .
The inverter will also shut down if the input voltage exceeds
15 .5V+/-0 .5V . This protects the inverter
against excessive input voltage . Although the inverter
has protection against over-voltage, it may still be damaged
if the input voltage were to exceed 16 volts .
18

Warranty

Notes
Warning

Troubleshooting Guide

Operation
Intro
Operation
Customer
Troubleshooting Guide
Assistance
Problem/Symptom
Possible Causes
Low output voltage
Overload
No output voltage
Low input
Installation
voltage
Secondary Icons
No output voltage
Thermal
after prolonged use
shutdown
Notice
Caution
No output voltage,
High input
"Protect" indicator
voltage
lighted
No output voltage
Short circuit
No output voltage
Inverter
switched off
No power
to inverter
Reverse
DC polarity
Low battery alarm
Poor DC wiring
on all the time
Poor battery
condition
Warranty
Solution
Reduce the load .
Recharge battery .
Notes
Check connections
and cable .
Allow inverter
to cool off .
Reduce load,
continuous
Warning
operation input
current required .
Improve ventilation;
Make sure ventilation
openings in the
inverter are not
obstructed .
Reduce ambient
temperature .
Make sure
the inverter is
connected to
12V battery .
Check regulation
of charging system .
Check load for
proper operation .
Turn inverter on .
Check wiring
to inverter .
Observe
correct polarity .
Check connections .
Make sure battery
is fully charged .