Electrical Alignment; Preparation - Sony RM-B150 Maintenance Manual

Remote control unit
Hide thumbs Also See for RM-B150:
Table of Contents

Advertisement

3-1. Preparation

Measuring Equipment
. Waveform monitor/Vectorscope
. Color monitor
Peripheral Equipment
. BVP-550/550P + CA-530/570 series + OHB-450/550 series, or
BVP-950/950P + CA-530/550/570 series + OHB-730/750A series
. AC adaptor AC-550/550CE, or DC variable power supply
Connection
COLOR VIDEO CAMERA
BVP-950/550 series
CAMERA ADAPTOR
CA-570/530 series
CCD UNIT
OHB series
REMOTE
*
DC IN
AC ADAPTOR
AC-550/550CE
or DC variable power supply
If using a DC variable power supply to drive power, connect the positive (+) side of the power supply to
pin 4 of the DC IN connector on the camera adaptor, and negative (_) side to pin 1.
n
When the power is supplied via the DC IN connector, be sure to press the micro switch on the DC IN
connector, that turns on the power. It is recommended to use an XLR plug when driving power via the
DC IN connector.
Initial settings
. ACTIVE button/Control panel:
. OUTPUT switch/Control panel:
. DISPLAY switch/Menu panel:
. CABLE COMP SELECT
*1: To select the cable length, use the menu of this unit. For details, refer to the operation manual supplied with the unit.
RM-B150
Section 3

Electrical Alignment

Tektronix 1780R (for NTSC)/1781R (for PAL) or equivalent
REMOTE CABLE
(supplied with RM-B150,10 m)
*
Micro switch
_
ON (lit)
BARS
OFF
*1
:
10 m
MONITOR
A-ch
REMOTE
75 Z
CONTROL UNIT
RM-B150
1
4
+
2
3
Waveform monitor/
Vector scope
PIX
Color monitor
Z
75
3-1(E)