STEP 7: CALCULATE THE VENTILATION REQUIREMENT
A. The MINIMUM ventilation requirement is calculated using ASHRAE 62.2-2004.
ASHRAE Airfl ow In CFM = [House Area in Sq Ft x 0.01] + [No. Bedrooms +1 x 7.5]
Use the Number of Bedrooms (Plus 1) or the Number of Occupants, Whichever Is Larger
Additional ventilation may be required for pets, hobbies,
fi replaces and attached garage, etc. Use your judgement.
B. This Table shows calculated airfl ow values at the nearest 5 CFM.
If more outdoor air is required than the Vent Control can deliver,
a 2nd device is advised. Consult with the homeowner.
C. Indicate the required CFM below.
STEP 8: DETERMINE THE VENT CONTROL'S FRESH AIR DELIVERY RATE
AIRFLOW DELIVERY VS NEGATIVE STATIC PRESSURE AS MEASURED FOR RETURN DUCT OR PLENUM (IN WC)
0.05
DUCT
LENGTH
FLEX
PIPE
10 FT
60
65
20 FT
55
60
30 FT
50
55
A. Measure the negative static pressure of the return system and consult table above for approximate inlet airfl ow. But these values are
estimates. An airfl ow measuring device (Nailor-Hart, etc.) will give the Vent Control's airfl ow exactly.
B. For the Table above the fl ex duct is laid loose with 2 wide 90° bends, and the damper is full open. For the rigid pipe the values are
based on two 90° elbows, and the damper is open. For both cases the air intake is through a metal vent hood with a bird screen.
Adjust airfl ow up or down for variations, including one elbow or bend, or the length of duct you're using isn't listed, etc.
C. Measure the delivered airfl ow or determine from above chart and record below.

INSTALLATION TEMPLATE

4-11/16" x 2-15/16" cutout
0.10
0.15
FLEX
PIPE
FLEX
85
90
105
80
85
100
75
80
95
Sharp edges can cause injury from cuts. Use gloves when cutting plenum
openings or handling ductwork.
1. Do not mount Vent Control on supply side. The unit will malfunction at
heated temperatures.
2. When installing the Vent Control on downfl ow furnaces make sure
blower continues to run after burner shuts off to prevent high heat
damage to the Control
3. Do not mount the Vent Control downstream of the fresh air intake, or a
humidifi er or bypass outlet. False humidity levels can cause the Control
to malfunction.
Minimum CFM Per Number Bedrooms
HOUSE
SQ FT
2
1000
35
1500
40
2000
45
2500
50
3000
55
3500
- - -
0.20
PIPE
FLEX
PIPE
110
120
125
105
115
120
100
110
115
WARNING
CAUTION
4
3
4
5
40
50
- - -
45
55
60
50
60
65
55
65
70
60
70
75
- - -
75
80
0.25
0.30
FLEX
PIPE
FLEX
135
140
150
130
135
140
125
130
130
6
- - -
70
75
80
85
90
PIPE
160
150
140

Advertisement

loading

This manual is also suitable for:

8126