Controlling 64 Cameras X 64 Monitors (Full Cross Point) - Siemens VIS3I-328 Installation Manual

Integrated system unit
Table of Contents

Advertisement

9.6.7

Controlling 64 cameras x 64 monitors (full cross point)

44
Siemens Building Technologies
Fire Safety & Security Products
A second bridge mode, bridge mode B, provides full cross point switching. Up to a
maximum of 64 cameras are available with the restriction that coaxial telemetry (C
Type) is only available when cameras are switched to monitors 1 to 16. The
camera inputs are connected from one 'monitor node'to the next via loop-through
cables, giving all monitors access to all cameras. The filtering on the loop-through
connections limits the availability of C Type telemetry and also some camera signal
degradation may occur as it passes down the chain of loop-through circuits.
Camera control over RS422/RS485 is fully supported.
NOTE
Alarm handling and multi-hop networking are not supported in bridge mode B
The special network address mode used to select bridge mode B is detailed in
Tab. 34.
Bridge Unit
'Monitor Node'
Network Address
Cams
B0
32
B1
64
Bridge mode B network address settings
Tab. 34
The PCCON networking connections are as bridge mode A and again the bridge
node serial port used determines the monitor numbers allocated to the monitor
node, as per Tab. 35.
Bridge Node
'Monitor Node'
Serial Port
Cameras
1
1 to 64
2
1 to 64
3
1 to 64
4
1 to 64
Bridge mode B addressing
Tab. 35
Fig. 15
Bridge mode B layout; 64 x 64 full cross point
A
Cameras 1 to 64
B
VIS3I-328 Monitor Node
C
Monitors 1-16
D
Monitors 17-32
E
Monitors 33-48
F
Monitors 49-64
G
VIS3I-328 Bridge Unit
'Monitor Node'
×
Network Address
Mons
×
00
16
×
00
16
'Monitor Node'
Monitors
1 to 16
17 to 32
33 to 48
49 to 64
VIS3I-328
Total
Needed
×
Cams
Mons
5
32 ×
64
9
×
64
64
10.2008

Advertisement

Table of Contents
loading

This manual is also suitable for:

Visilynx 3

Table of Contents