Typical Hot Tub Wiring Diagrams A-B (North American 60 Hz Models Only) - Sundance Spas Altmar Owner's Manual

880 series
Table of Contents

Advertisement

880 SERIES
20.0
Typical Hot Tub Wiring diagrams A-B (North Ameri-
can 60 Hz Models Only)
2-Pole Circuit Breaker with 2-Wire Grounded Load Connection
A
White (N)
Main
Service
Panel
with
GFCI
B
Main Panel*
240 VAC
*GFCI Sub Panel commonly
used when recommended GFCI
does not install in Main Panel.
Page 84
(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)
240 VAC
Black (L1)
Red (L2)
Pigtail
Neutral Bus
Ground
Main Panel with Secondary GFCI Shut-Off Box Using a
2-Pole GFCI Breaker with 2-Wire Grounded Connection
(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)
Red (L2)
Black (L1)
White (N)
Green (Ground)
2-Pole
GFCI
Breaker
Red (L2)
Black (L1)
Green
No Load Neutral Wire
GFCI Sub Panel*
2-Pole
GFCI
Breaker
Red (L2)
Black (L1)
Green
Pigtail
Neutral Bus
Ground
TB1
R
B
TB2
Ground/Bonding Lug**
Note: service disconnect not
shown in this diagram.
The control box TB1 terminal
position varies between models.
TB1
R
B
TB2
Ground/Bonding Lug**
No Load Neutral Wire
Note: service disconnect not
shown in this diagram.
The control box TB1 terminal
position varies between models.
DANGER
!
RISK OF SHOCK OR
ELECTROCUTION!
Turn power off
before servicing. This
task should only be
performed by a quali-
fied technician.