6.1.3.2

Indicators on the hard disk drives

Figure 11: Indicators on the 2.5 inch HDD modules (A) and on the 3.5 inch HDD modules (B)
1 HDD / SSD FAULT (orange)
(in conjunction with a RAID controller)
– Does not light: no HDD / SSD
– Lit (green): HDD / SSD is inserted
– Lit (red): HDD / SSD Faulty (drive defective/needs replacing, drive
failed, drive deactivated by software or the HDD/ SSD module is not
correctly inserted)
– Slow flashing (amber/red alternately): HDD / SSD Rebuild (the data
is being restored after changing a drive)
– Fast flashing (amber): HDD / SSD Identify
2 HDD / SSD activity indicator
– Lit (green): HDD / SSD in active phase (drive active, drive being
accessed)
– Does not light: HDD / SSD inactive