Miele G1000 Technical Information page 144

Miele dishwashers technical information
Table of Contents

Advertisement

Technical Information
Flashing
Rhythm of
Function
Intake/Drain
Lt.
Pos. 26:
Long Short
Add second
interim rinse
2
6
Pos. 27:
Long Short
Extended
drying time
2
7
Pos. 36:
Long Short
Machine
height
setting *1
3
6
Table 6-27: G1180 / G2180 Programming Mode Options (Cont. from Table 6-26) (Cont. on Table 6-28)
Programming
Press the Program
The Intake/Drain
button 26x.
LED flashes 2x
long and 6x briefly
To change the
intermittently.
setting, press the
Program button
The SaniWash
and hold it until the
LED is off =
Intake/Drain LED
program cycle per
flashes. Then press
factory setting; The
the Program button
SaniWash LED
to enter the desired
flashes = second
setting changes. *2
interim rinse is
added.
Press the Program
The Intake/Drain
button 27x
LED flashes 2x
long and 7x briefly
To change the
intermittently.
setting, press the
Program button
The SaniWash
and hold it until the
LED if off = normal
Intake/Drain LED
drying (factory
flashes. Then press
setting); the
the Program button
SaniWash LED
to enter the desired
flashes = enhanced
setting changes. *2
drying.
Press the Program
The Intake/Drain
button 36x.
LED flashes 3x
long and 6x briefly
To change the
intermittently.
setting, press the
Program button
The SaniWash
and hold it until the
LED is off = normal
Intake/Drain LED
machine height
flashes. Then press
(G1xxx). The
the Program button
SaniWash LED
to enter the desired
flashes = XXL units
setting changes. *2
(G2xxx).
144
G1000 / G2000 Dishwashers
Flashing Rhythm of
Indication
SaniWash LED
Long
-
-
Long
-
-
Long
-
-
Short Display
-
P0
1
P1
Short Display
-
P0
1
P1
Short Display
-
P0
1
P1

Hide quick links: