0: OFF
1: ON
[Parameter 2] <Read beginning column (0 - 1472)>
[Parameter 3] <Read ending column (127 - 1599)>
[Process] Sets the beginning column and ending column
numbers for reading during horizontal partial scan
operation.
Set the number of columns to read to a number
between 128 and 1600.
Note
Depending on the setting for the number of lines or
number columns to read, images prior to configuration
may appear in the disabled image display areas. Refer to
the operating instructions for the interface board, and
enable compatibility with camera file settings.

IN/OUT Setting Command

x External Trigger Signal Input Selection
[Command] EXTTRG
[Parameter 1] <Input specification (0 - 1)>
0: Camera Link
t DIGITAL IF connector
1: DC
t DC IN connector
[Process] Selects an input route of the external trigger
signal.
x Grayscale Output Setting
[Command] GRAYSCALE
[Parameter 1] <Mode (0 - 1)>
0: OFF
1: ON
[Process] Sets the grayscale mode.
x DC IN Connector Signal Output Setting
[Command] WEN-STRB
[Parameter 1] <Specification for 10th pin output (0 - 2)>
0: GND output
1: DVAL output
2: EXPOSURE output
[Process] Sets the 10th pin of DC IN connector signal
output specification.
x Signal Output Bit Depth
[Command] BIT-DEPTH
[Parameter 1] <Signal Output Bit Depth (0 - 2)>
0: 12 bit output
1: 10 bit output
2: 8 bit output
[Process] Sets the signal output bit depth.
Note
This can also be changed with the IMG-WIZE
command.
36
Command Specification
x Serial Transmission Speed Setting
[Command] BRATE
[Parameter 1] <Baud rate (0 - 3)>
0: 9600 bps
1: 19200 bps
2: 38400 bps
3: 57600 bps
[Process] Sets the serial transmission speed.

Setting Value Control Command

The setting value control command controls camera
setting data saved in the EEPROM inside the camera.
The following list shows the contents.
Command
Explanation
Initialization
Initializes the data corresponding to the
of setting
camera control command to the factory
value
setting value.
Save setting
Writes the data corresponding to the camera
control command in the EEPROM.
Read setting
Reads the data corresponding to the camera
control command in the EEPROM.
Setting value
Sends the necessary data to the camera
accession
control application.

Setting Initialization Command

x Initialization of Setting
[Command] INIT
[Process] Initializes the data corresponding to the
camera control command to the factory setting value.
However, the settings are not saved (SAVE).

Save Setting Command

x Save Setting
[Command] SAVE
[Process] Writes the data corresponding to the camera
control command in the EEPROM.
Another command is not accepted during execution
of the process. After completion of execution, the
following message is displayed.
"OK": Normal completion
Note
If the completion is not normal, the saved data may be
damaged.

Read Setting Command

x Read Setting
[Command] LOAD
[Process] Reads the data corresponding to the camera
control command in the EEPROM.