Jøtul GF 370 DV Installation And Operation Instructions Manual

Jøtul GF 370 DV Installation And Operation Instructions Manual

Jotul gf 370 dv direct vent gas stove

Advertisement

CAUTION: THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call you gas supplier from a
neighbor's phone. Follow the gas supplier's
instruction.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall be
installed in the same room as the appliance.
Installation and

Operation Instructions

ATTENTION : CES INSTRUCTIONS DOIVENT
DEMUERER AVEC LE PROPRIÉTERE D'UNE
MAISON.
AVERTISSEMENT: Assurez-vous de bien suiv-
reles instructions données dans cette notice
pour réduire auninimum le risque d'incendie
ou d'explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d'essence ni
d'autres vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout
autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
• Ne pas tenter d'allumer l'appareil.
• Ne touchez à aucum interrupteur. Ne
pas vous servir des téléphones se trou-
vant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
• Si vou ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L'installatione l'entretien doivent être
assurés par un installateur ou un service
d'entretien qualifié ou par le fournis-
seur de gaz.

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GF 370 DV

  • Page 1: Operation Instructions

    Installation and Operation Instructions ATTENTION : CES INSTRUCTIONS DOIVENT CAUTION: THESE INSTRUCTIONS ARE TO DEMUERER AVEC LE PROPRIÉTERE D’UNE REMAIN WITH THE HOMEOWNER. MAISON. WARNING: If the information in these AVERTISSEMENT: Assurez-vous de bien suiv- instructions is not followed exactly, a fire reles instructions données dans cette notice or explosion may result causing property pour réduire auninimum le risque d’incendie...
  • Page 2: Installation & Service Tools

    • External regulator (for Propane only) number in the space below. • Piping which complies with local code • Manual shut-off valve - MODEL NAME: Jøtul GF 370 DV Gas Stove T-Handle required in Massachusetts • Sediment trap SERIAL NUMBER:_______________________________ •...
  • Page 3: Table Of Contents

    Safety Information ........6 . Confirm stove contents. Installation Hearth Requirements ......7 The Jøtul GF 370 DV includes the following loose Clearances ..........7 items shipped in the Miscellaneous Hardware bag; Vent Requirements • 4 mm hex key - used to remove the Approved Vent Manufacturers ..
  • Page 4: Specifications

    High Altitude Adjustment Kit, LP ....... #156821 Wisconsin. High Altitude Adjustment Kit, NG ....#156822 In addition, the Jøtul GF 370 DV has been tested and listed as a direct vent gas fireplace heater and listed to ANSI Z21.88-2005, ANSI z21.88a/CSA 2.33a- ������...
  • Page 5: General Information

    General Information and legal installation. Some areas require a permit THIS HEATER MUST BE INSTALLED AND MAIN- to install a gas burning appliance. Always consult TAINED BY A QUALIFIED SERVICE AGENCY. your local building inspector or authority having DO NOT ATTEMPT TO ALTER OR MODIFY THE jurisdiction to determine what regulations apply in CONSTRUCTION OF THIS APPLIANCE OR ITS COM- your area.
  • Page 6: Safety Information

    Safety Information WARNING! Due to the high operating temperatures this ap-  Shock Hazard. Can cause severe injury or death. pliance should be located out of traffic and away This appliance is powered by line voltage. Do from furniture, draperies, etc. Maintain proper not try to repair the components in this appli- clearance to combustible mantels and fireplace ance.
  • Page 7: Installation

    �� Hearth Requirements Figure 4. Alcove and Wall Clearances. ALCOVE SPECIFICATIONS: The Jøtul GF 370 DV has been approved for installa- tion directly on combustible floor materials, including Maximum Alcove Depth: 21 3/4” (55.2 cm) carpeting. No additional floor protection is required, Minimum Alcove Width: 31 1/4”...
  • Page 8: Approved Vent Manufacturers

    Vertical Venting and Termination Approved Vent Manufacturers The Jøtul GF 370 DV can be vertically vented through a roof or ceiling. Follow these guidelines The Jøtul GF 370 DV stove is approved for installation with direct vent chimney components supplied by Steep roofs, nearby trees, or predominantly windy ...
  • Page 9: Masonry Chimney Conversion

    Figure 8. Vent System through a masonry chimney using the Simpson Dura-Vent Chimney Conversion Kit The GF 370 DV is approved for use with direct vent #934. Other manufacturers use similar designs. May chimney conversion kits in a masonry chimney or a prefabricated solid fuel listed chimney.
  • Page 10: Horizontal Termination

    Horizontal Termination Figure 9. Minmum vent pipe sections required for Minimum vertical rise from the vent collar is a 24”  horizontal termination. ��� section vent pipe. See fig. 9. A maximum of two 90° or four 45° elbows may be ...
  • Page 11: Vent Termination Clearances

    Figure 12. Horizontal termination clearances A = Clearance above grade, veranda, porch , deck, or balcony G = Clearance to inside corner: ** Min. 6 inches, U.S. / *12 : 12 inches (30 cm) minimum. inches (30 cm) CAN. We strongly recommend 12 inches, particularly where windy conditions prevail.
  • Page 12: Vent Restriction Adjustments

    Vent Restriction Adjustments The Jøtul GF 370 DV features adjustment controls for Exhaust Restrictor Adjustment both intake air and exhaust to accommodate a variety 1. Remove the Trim Rings from the Top Plate. of conditions that result from variables inherent in the 2.
  • Page 13: Vent Termination Diagram

    A maximum of two  ������ 90° or four 45° elbows ��������� may be used. When- ���� ever possible, use 45° � elbows instead of 90° elbows as they of- fer less restriction to ������ � � � � � � � � the flow of flue gases ��������...
  • Page 14: Stove Assembly

    Stove Assembly 1. Glass Frame Removal To access the firebox, use the 4 mm hex key to remove the four socket head screws that attach the glass frame to the firebox. See fig. 18. . Routing the Power Supply The power cord located in the valve compartment is connected to the Fan Control Module which is the main power supply for all stove operating functions.
  • Page 15: Gas Pressure

    ��������������� ������������� ����������������� Inlet Pressure �������������� Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa) Propane: 12.0 WC (2.99 kPa) 14.0 WC (3.48 kPa) ���������������� Manifold Pressure ���������� Natural Gas: 1.6 WC (0.398 kPa) 3.5 WC (.87 kPa) Propane: 6.4 WC (1.59 kPa) 10.0 WC (2.48 kPa) ����������...
  • Page 16: Fuel Conversion

    • Label B - apply to the rating plate in the space indi- cated on the plate. • Small valve label - apply to valve body The GF 370 DV gas stove is shipped from the factory • Conversion instructions equipped to burn either Natural or Propane gas. Fuel...
  • Page 17 Pilot Head Pilot Orifice Ignitor Flame Sensor Primary Air Shutter Retainer Clip Injector Regulator Diaphragm Regulator Tower Use new Torx screws supplied Figure 23. Fuel conversion components and assemblies pilot orifice. Replace it with the orifice from the 11. Install the new variable regulator tower from the kit.
  • Page 18: High Altitude Adjustment

    7. Firebox Panel Installation 6. High Altitude Adjustment for Skamol Kit 15616 The decreased atmospheric pressure of higher alti- tudes affects heat value of gaseous fuels. Most gas Reflective Glass Kit 15617 suppliers derate the gas intended for use at eleva- tions above 2000 feet.
  • Page 19: Skamol Panel Installation

    Retainer Brackets Figure 26a. Figure 25a. Bracket screws Install Rear Glass Install Rear Skamol may be loosened Panel. Panel. slightly to ease panel installation. Rear Panel Figure 25b. Figure 26b. Install Rear Skamol Install Side Glass Panels. Panels. . Install Burner Media Wishing Rock CAUTION: THE ROCKS ARE FRAGILE! SUPPORT THE ASSEMBLY FROM THE BOTTOM AND HANDLE CARE-...
  • Page 20: Log Set Installation

    Install the Log Set The three-piece log set includes a bag of ember stones that simulate glowing coals when the burner is operating. Use workgloves and handle the individual logs carefully, supporting each with both hands. Install the Logset and Ember Stones as shown in figures 28-31.
  • Page 21: Outer Decorative Glass Panels

    . Exterior Decorative IMPORTANT! Clean the inside surface of the glass before installation. Glass Panel Kit Assembly Before mounting the support brackets to the stove set each on the end of the glass panel and bend the bracket tabs to hold the panel securely. Kit Contents See Detail A, fig.
  • Page 22: System Check

    10. Initial System Check Open outlet The burner and fan control system consists of the fol- Accent Lamp - not used lowing built-in or supplied components: 1) Remote Transmitter - 3, AAA batteries preinstalled 2) Remote Receiver - 4, AA backup batteries preinstalled �����...
  • Page 23: Flame Picture Adjustment

    Flame Appearance / Air Shutter Adjustment WARNING: AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE PERFORMED BY A QUALIFIED, PROFESSIONAL SERVICE TECHNICIAN. Locate the Primary Air Shutter control under the fire- box floor above the gas valve. See fig. 37. The shutter is set at the midpoint of its adjustment range at the factory.
  • Page 24: Operation

    Jøtul GF 370 DV Ignition Module This is the brain of the system. It allows the pilot to be Operation set up as an IPI or CPI unit. It tells the burner to light or turn off, and provides the ignitor with the electric- ity needed for sparking.
  • Page 25: Control Functions

    Control Functions CPI (Continuous Pilot Ignition) Pilot Mode IPI (Intermittent Pilot Ignition) In most cases you will want to operate the stove in IPI mode. This allows the most efficient use of gas, burn- ing the pilot light only when the thermostat calls for Accent Lamp the burner to ignite.
  • Page 26 Remote Transmitter Controls, cont’d. Temperature Indication Display W ith the transmitter in the OFF position, press the  Thermostat Key and the Mode Key at the same time. The display screen will show the current room temperature cycling between Farenheit and Celsius Figure 42.
  • Page 27 SMART Thermostat Function This function adjusts the flame intensity according to the difference in the Set Point temperature and the actual room temperature. As the room temperature gets closer to the Set Point, the Smart Function will modulate flame intensity down. To activate this function, press the Thermostat Key ...
  • Page 28: Wiring Diagrams

    Output voltage/frequency/current: 120V / 60 Hz / 5 A Auxiliary switched output: 120V / 60 Hz / 2 A Figure 59. Wiring Diagram - GF 370 DV Fan Fan speed output: 120V / 60 Hz / 1 A Remote Control Transmitter Supply voltage: 4.5 V (three 1.5V AAA batteries)
  • Page 30: Maintenance

    Maintenance FOR REPLACEMENT, USE ONLY JØTUL CERAMIC GLASS PANEL KIT 15617. DO NOT USE ANY OTHER TYPE OF GLASS WITH THIS This appliance and its venting system should be APPLIANCE. inspected before use and at least annually by a quali- fied service technician.
  • Page 31: Battery Replacement

    Initializing the Remote Control Figure 61. Each time you replace the batteries, you will need to 156817 Glass initialize communication between the Receiver and Replacement the Transmitter. Kit includes gasket and spare 1. Place the slider switch in the REMOTE position. retainer clips.
  • Page 32: Illustrated Replacement Parts

    �� � �� �� �� �� � �� �� � � �� �� �� � � � �� �� � �� �� �� �� � �� � �� �� � � � �� �� �� �� � � � �� �...
  • Page 33 �� � �� � �� �� �� � �� �� �� �� � �� � �� � �� �� � � �� �� �� �� � �� � �� �� � � �� �� � � �� �� � �� �...
  • Page 34 Figure 66. Spud Assembly parts identification...
  • Page 35 Part Number Description 118200 Screw, #8 X 3/8”, Taptite, SLHWH, SZPL Use only genuine Jøtul Replacement Parts 117917 Screw, HWH SMA 8 x 1/2 SL Blk Oxide available from your local Authorized Jøtul 117967 Screw, Pan Head #7 x 3/8 PH SMA Zinc Dealer or by contacting: 117968 Nut, M6 Serrated Flange plain...
  • Page 36: Mobile Home Installation

    Appendix A Mobile Home Installation Correct Flame Pictures The Jøtul GF 370 DV can be installed for use in a mobile home in the U.S. and Canada provided: 1. The stove must be secured to the floor of the mobile home. There is a hole for this purpose,...
  • Page 39: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance is equipped with an ignition device which automatically lights the pilot.
  • Page 40 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that the these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in specifi- cation, color or type of accessories from those illustrated or described in various publications.

Table of Contents