Emc Installation Guidelines - Raymarine ST70 User Reference Manual

Autopilot controller
Hide thumbs Also See for ST70:
Table of Contents

Advertisement

iv

EMC installation guidelines

Raymarine equipment and accessories conform to the appropriate Electromagnetic
Compatibility (EMC) regulations. This minimizes electromagnetic interference
between equipment, which could otherwise affect the performance of your system.
Correct installation is required to ensure that EMC performance is not compromised.
For optimum EMC performance, we make the following recommendations:
Place Raymarine equipment and cables at least 3 ft (1 m) from any equipment that
transmits, or cables that carry, radio signals from VHF radios, cables and anten-
nas. In the case of SSB radios, the distance should be increased to 7 ft. (2 m).
Place Raymarine equipment and cables more than 7 ft (2 m) from the path of a
radar beam. A radar beam can normally be assumed to spread 20 degrees above
and below the radiating element.
Use a power source separate from that used for engine-start. This is important to
prevent erratic behavior and data loss which can occur if the engine-start does not
have a separate battery.
Use Raymarine-specified cables.
Do not cut or extend cables unless doing so is detailed in the installation manual.
Remember
Where constraints on the installation prevent any of the above recommendations:
Always allow the maximum separation possible between different items of electri-
cal equipment.
This will provide the best conditions for good EMC performance of the installation.
Suppression ferrites
Raymarine cables may be fitted with suppression ferrites. These are necessary for
correct EMC performance. Any ferrite removed during installation must be replaced
as soon as installation is complete.
Use only ferrites of the correct type, supplied by Raymarine authorized dealers.
Connections to other equipment
If Raymarine equipment is to be connected to other equipment using a cable not
supplied by Raymarine, a Raymarine suppression ferrite MUST always be attached
to the cable near the Raymarine unit.
General cabling guidelines
Do not mix AC and DC cables.
Adhere to EMC guidelines (above).
Use Kopex conduit where appropriate to protect cables.
Label all cables for easy identification.
Keep fluxgate compass cable separate from other cables.

Hide quick links: