Dyna-Glo RMC-FA150NGDGD Operating Instructions & Parts Manual page 4

Dyna-glo delux natural gas construction heater
Table of Contents

Advertisement

Available languages

Available languages

Dyna-Glo Delux Operating Instructions and Parts Manual
Dyna-Glo
Construction Heater
Installation
E
Review and under­
WARNING
stand all of the
N
warnings in the Safety Information
G
Section on pages 1–3. They are required
L
to operate this heater safely. Follow all
local and state codes when operating this
I
heater.
s
Be sure to test all
WARNING
H
connections for leaks
after installation or service. Never use an
open flame to check for leaks. Apply a
50/50 mixture of dish soap and water to
each connection. If bubbles appear, there
is a leak. Correct all leaks immediately.
1. Provide the natural gas supply system
(see Natural Gas supply, on page 3).
2. Connect all plumbing and fittings
to the low-pressure Natural Gas
source. This source must be regulated
to a maximum of 1/2 PsI, and the
piping must be a 3/4 inside diameter
minimum, and not be over 10 feet
in length.
3. Line up the female threaded end
of the hose with the fitting on the
heater base and tighten.
4. slowly open valve at natural gas
supply.
5. Check for leaks at all connections.
Inlet Connector
Figure 3 – Hose and Inlet Connector
For Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST
Delux Natural Gas
®
WARNING
making the proper connections, be
sure to check for leaks. Apply a 50/50
mixture of dish soap and water to all
connections. Bubbles forming are
evidence of a leak. Be sure to correct
all leaks at once!
6. Close natural gas supply.
Operation
WARNING
warnings in the Safety Information
Section on pages 1–3. They are required
to operate this heater safely. Follow all
local and state codes when operating this
heater.
TO START HEATER
1. Follow all safety, installation and
ventilation instructions in this
manual.
2. Position the heater on a stable and
level surface, and be sure that no
drafts blow into the inlet or outlet of
the heater.
3. Plug the power cord of the heater
into a three hole grounded extension
cord. Be sure that the extension cord
is at least 6 feet long, and is UL listed.
EXTENSION CORD WIRE SIZE
REQUIREMENTS
• Up to 50 feet long, use 18 AWG rated
cord.
• 51 to 100 feet long, use 16 AWG rated
cord.
• 101 to 200 feet long, use 14 AWG
rated cord.
Hose
4. Following the extension cord
After installing all
requirements, plug the extension
gas piping, and
cord into a 120 volt/60 Hertz, three
hole grounded outlet.
5. Open gas supply valve slowly.
6. Rotate on/off switch to the ON
position. set thermostat to desired
temperature. Thermostat setting may
be too low if heater does not start.
select a higher temperature and start
Review and under­
heater.
stand all of the
NOTE: If the heater does not ignite,
turn on/off switch to OFF position. Wait
for the safety control to reset (usually
about 10 seconds), and try again.
NOTE: If this does not work, the high
temperature switch may have opened
while the thermostat was shutting
down. Wait 10 to 15 minutes for the
switch to reset, then attempt to light
heater. Continued outages indicate a
system problem, have unit serviced
by a professional.
TO SHUT DOWN HEATER
1. shut off the gas supply by closing the
valve tightly.
2. After a few seconds, the heater will
burn off the gas that was left in the
supply line.
3. Turn on/off switch to the OFF
position.
4. Disconnect heater from power supply.
Maintenance
WARNING
while it is hot, operating or plugged
in. Severe burns or electrical shock
can occur.
1. Be sure to inspect the heater before
each use. Check for leaks using the
method described in Installation
section. Repair any leaks immediately.
4
RMC-FA150NGDGD
Do not attempt to
service the heater
www.ghpgroupinc.com