Alternate Vent/Flue Drain Hose Connections - Amana GUCA Installation Instructions Manual

Gas fired warm air furnace
Hide thumbs Also See for GUCA:
Table of Contents

Advertisement

LEFT
SIDE PANEL
FRONT COVER
DRAIN PORT
RED HOSE
CLAMP
HOSE A
SIDE PANEL
GROMMET
HOLES
TUBE(S) 2
DRAIN
TRAP
Upright "Standard" Connections
Left Side
(Upflow Shown, Counterflow Similar)
3. Cut and remove 1/4 inch from the end of the drain port
on the rubber elbow.
4. Insert Tube 1 into rubber elbow drain port and secure
with red hose clamp. Angle tube outward toward front
of furnace.
5. Right side drains
Cut 17 3/4 inches from the long end of Hose B and
discard. Secure the remaining hose to Tube 1 with a
green hose clamp. Route the other end of Hose B to
front right side panel grommet hole.
Left side drains
Cut "X" inches from the long end of Hose B and discard.
Refer to table for appropriate length to cut. Secure
remaining hose to Tube 1 with a green hose clamp.
Route other end of Hose B to front left side panel
grommet hole.
Cabinet Width
Model
(inches)
(kBTU Tons)
045__30
16 1/2
070__30
070__40
20 1/2
090__40
090__50
24 1/2
115__50
6. Insert short end of each Tube 2 through side panel
grommet holes. Secure tubes to Hose A and Hose B
with green hose clamps.
RUBBER
ELBOW
RUBBER
ELBOW
DRAIN PORT
RED HOSE
CLAMP
TUBE 1
GREEN HOSE
CLAMPS
(3 PLACES)
HOSE B
"X" Length Cut From
Long End of Hose B
(inches)
8 inches
4 inches
None
22
NOTE: Ensure hoses and tubes maintain a downward
slope for proper drainage and that they are not kinked or
binding.
For details concerning mounting of the drain trap, refer to
Section X, Condensate Drain Lines and Drain Trap - Up-
right Drain Trap Mounting.

Alternate Vent/Flue Drain Hose Connections

Upright installations using the alternate vent/flue outlet will
require "right-side only" drain hoses to be connected as
follows. Refer to Section IX, Vent/Flue Pipe and Combus-
tion Air Pipe for details on alternate vent/flue pipe connec-
tion.
1. Remove the rubber plug from the front cover right-side
drain port. Save for use in step 3.
2. Secure Hose A to front cover drain port with a red hose
clamp. Route hose to rear right side panel grommet
hole.
RUBBER ELBOW
(EXTERNALLY
MOUNTED)
FRONT COVER
DRAIN PORT
HOSE A
RED HOSE
CLAMP
TUBE(S) 2
Upright "Alternate" Connections
Right Side Only
(Upflow Shown, Counterflow Similar)
3. Remove grommet from front right-side panel drain
hole. Seal hole in grommet with large end of plug.
Reinstall grommet and plug into side panel drain hole.
4. Cut 1/4 inch from the end of the drain port on the
externally mounted rubber elbow. Discard cut portion.
5. Insert Tube 1 into rubber elbow drain port and secure
with a red hose clamp. Angle tube outward toward front
of furnace.
6. Cut 17 7/8 inches from the long end of Hose B and
discard.
7. Secure remaining end of Hose B to exposed end of
Tube 1 with a green hose clamp. Route hose toward
right side panel grommet holes.
8. Insert short end of one Tube 2 through rear right side
panel grommet drain hole. Secure tube to Hose A with
a green hose clamp.
9. Insert short end of remaining Tube 2 into Hose B from
rubber elbow and secure with green hose clamp.
NOTE: Ensure hoses and tubes maintain a downward
slope for proper drainage and are not kinked or binding.
For details concerning mounting of the drain trap, refer to
RUBBER
ELBOW
DRAIN PORT
RED HOSE CLAMP
TUBE 1 GREEN HOSE
CLAMPS
(3 PLACES)
HOSE B
SIDE PANEL
GROMMET
HOLES
DRAIN TRAP