Microwave Condition

Open door, place cup of water in oven.
Close oven door.
PREHEAT
Press
ON / OFF
START
Press
ITEM
STG
QTY
1
2
3
4
C M
LMT
PREHEAT
NOT
ITEM
STG
QTY
1
2
3
4
C M
LMT
PREHEAT
NOT
End of cycle tone sounds.
Open door and remove water.
Is water heated?
YES
MICROWAVE CONDITION
OPERATING PROPERLY
RS5320016
Rev. 0
enter
TIME
desired
time
POWER
COOK
READY
STANDBY
LEVEL
POWER
COOK
READY
STANDBY
LEVEL
NO
POWER
enter
TEMP
LEVEL
70 C
1. Inoperative top touch panel.
NO
2. Inoperative side touch panel.
3. Inoperative H.V. board.
4. Broken or loose wire connection.
Heats Slowly
1. Inoperative or misadjusted
interlock switch module.
2. Inoperative magnetron.
3. Inoperative thermal cutout.
4. Broken or loose wire connection.
No Heat
1. Inoperative or misadjusted
interlock switch module.
2. Inoperative thermal cutout.
3. Inoperative triac.
4. Inoperative diode.
5. Inoperative capacitor.
6. Inoperative H.V. transformer.
7. Inoperative magnetron.