Venting Installation; General Venting Information; General Venting Instructions - A.O. Smith BTH-120 Instruction Manual

Commercial gas water heaters series 100 & 101
Hide thumbs Also See for BTH-120:
Table of Contents

Advertisement

Breathing Hazard - Carbon Monoxide Gas
Install vent system in accordance with codes.
Do not operate water heater if flood damaged.
Special consideration must be taken with installations
above 10,000 feet (3,048 m) refer to high altitude
section of this manual.
Do not operate if soot buildup.
Do not obstruct water heater air intake with insulating
jacket or blanket.
Do not place chemical vapor emitting products near
water heater.
Gas and carbon monoxide detectors are available.
Never operate the heater unless it is vented to the
outdoors and has adequate air supply to avoid risks
of improper operation, fire, explosion or asphyxiation.
Analyze the entire vent system to make sure that
condensate will not become trapped in a section of
vent pipe and therefore reduce the open cross
sectional area of the vent.
Breathing carbon monoxide can cause brain damage or death.
Always read and understand the instruction manual.
Never operate the water heater unless it is vented to the outdoors.
The instructions in this section of the manual must be followed
to avoid choked combustion or recirculation of flue gases. Such
conditions cause sooting of the combustion chamber, burners
and flue tubes and creates a risk of asphyxiation.

general Venting information

The water heaters covered in this manual are operationally
equivalent to Category IV appliances and may be installed in
either a Power Vent or Direct Vent configuration.
category iV appliance
Category IV appliances operate with a positive vent (exhaust)
static pressure and with vent gas temperatures low enough to
produce condensate in the vent piping.
power Vent configuration
Power Vent configurations derive all combustion air from the
room where they are installed and discharge all flue gases to
the outdoor atmosphere through a sealed vent (exhaust) pipe.
Power vent configurations have one vent pipe connected to the
water heater which can be terminated in a vertical or horizontal
arrangement. See Figure 40 and Figure 41 on page 34.
direct Vent configuration
Direct Vent configurations derive all combustion air directly from
the outdoor atmosphere through a sealed intake air pipe and
discharge all flue gases to the outdoor atmosphere through a
sealed vent (exhaust) pipe. Direct Vent configurations have two
pipes connected to the water heater, one vent pipe and one
intake air pipe. Direct Vent configurations can be terminated in
one of six different arrangements. See Figure 42 on page 34
through Figure 47 on page 35.

general Venting instructions

These instructions must be followed on all installations.
1. Do NoT install the water heater in a Power Vent configuration
unless there is adequate supply of fresh air, see Air
requirements on page 18. If the installation space does
not provide an adequate supply of fresh air the water heater
must be installed in a Direct Vent configuration.

Venting installation

2. If the water heater is to be installed in a beauty shop,
3. The vent and intake air piping must terminate outdoors.
4. The minimum clearance from combustible materials for the
5. The water heater must be protected from freezing downdrafts
6. The vent (exhaust) pipe must not be combined or connected
7. The intake air pipe must not be combined or connected to
8. Locate the water heater where the vent (exhaust) and intake
9. Do not install the vent or intake air piping in a manner that will
10. Vent pipes must be pitched a minimum of a 1/4 inch per foot
11. Do not anchor the vent or intake air pipe directly to framed
12. Use only approved vent/intake air pipe sizes and materials.
13. Use only factory supplied vent and intake air or concentric
14. Do not locate the vent (exhaust) or intake air terminations
15. Direct venting into dead air spaces such as alleys, atriums,
16. Do not locate the vent termination over a public area where
17. Ensure the screens in the factory supplied terminations are
18. Stress levels in pipe/fittings can be significantly increased by
19. Ensure the intake air connection Tee fitting is oriented properly
20. Carefully read the Venting requirements on page 24 and then
22
barber shop, cleaning establishment, a laundry with dry
cleaning equipment or any space with contaminated air it is
imperative that the water heater(s) be installed in a Direct
Vent configuration so that all air for combustion is derived
from the outdoor atmosphere.
vent (exhaust) and intake air piping shall be 0 inches. Vent
piping passing through a combustible wall or ceiling must be
a continuous run (no joints).
during shutdown periods.
to any other appliance's vent system or chimney.
any other appliance's intake air piping.
air piping will remain within the maximum equivalent lengths
allowed. See Venting requirements on page 24.
allow water to be trapped in the piping.
back to the water heater (to allow drainage of condensate).
walls, floors or ceilings unless rubber isolation pipe hangers
are used to prevent vibration noise from being transmitted.
See Venting requirements on page 24.
terminations. See the Venting requirements on page 24.
where they would be objectionable due to noise at the
termination(s). This includes locations close to or across from
windows and doors.
and inside corners can cause recirculation of flue gases.
recirculation of flue gases will cause sooting, premature
failure of the heat exchanger and icing of the combustion
air intake during severe cold weather. To prevent the
recirculation of flue gases, maintain as much distance as
possible between the intake air and vent terminations.
condensate or vapor can cause a nuisance or ice hazard.
securely installed to prevent blockage in the vent system.
improper installation. If rigid pipe clamps are used to hold
the pipe in place, or if the pipe cannot move freely through a
wall penetration, the pipe may be stressed, or high thermal
stresses may be formed when the pipe heats up and expands.
Install accordingly to minimize such stresses.
on BTH 199/250 models, see page 23 for instructions.
proceed to the Venting Installation Sequence on page 25.