When a hard drive fails or becomes corrupted RAID 1 provides a the feature to enable the Auto Rebuild configuration. This configuration will take the information from one of
the existing hard drives and rebuild the new hard drive with the same information to get the RAID 1 configuration completed.
Information:
To view the hard drive status you can got to STATUS
> SYSTEM INFO and monitor the Sync Time
Remaining field. If it displays 'Completed' the RAID 1
configuration is functioning normal.
Degraded:
However if it displays 'Degraded' then one of the hard
drives have either failed or is starting to fail. This mean
that the problematic hard drive needs to be replaced.
Step 1:
After the new hard drive is inserted into the DNS-343
go to ADVANCED > RAID and you'll now have the
option to start the Auto Rebuilding process if Auto
Rebuild was disabled from the beginning. If Auto
Rebuild was enabled from the beginning the DNS-343
will start this Rebuilding process automatically.
You can now click the Manually Rebuild Now button to
initiate the Auto Rebuilding process.
D-Link DNS-343 User Manual

RAID 1 Recovery - Auto Rebuilding