TO CONVERT APPLIANCE F ORUSEWITHNATURAL G AS
Propane Gas(LP)To Natural G as
Model- JGD8348BDP
Conversion
Instructions
Manifold - Natural Gas pressure required - 5" W.C.
If this appliance has been converted for use with LP Gas,
Incoming Natural Gas pressure required to appliance
each of the following modifications must be performed to
pressure regulator - 6" - 7" W.C.
convert the unit back to Natural Gas.
Natural Gas input specified - 56,000 BTU/hr.
A. Replace all orifice hoods - Perform steps 1 through 4 on
page 7. Locate the (6) six Natural Gas hoods (with small
numbers stamped on their sides saved from the original
Natural Gas unit). Page 5 Illustration "E'. The two
hoods with .0520 (#55 orifice) stamped on them are for
the left front and left rear burners. The four hoods with
the .0595 (#53 orifice) stamped on them are for the two
right burners.
To make these conversion adjustments follow the
instructions and illustrations ("A" through "E") pages
5-7.
B. Invert cap in appliance pressure regulator (see
Illustration "D", page 6). With the appliance installed,
the appliance pressure regulator is located on the right
underside of the appliance at the inlet to the gas
manifold. Identify the type of appliance pressure
regulator on the unit and follow the instructions in the
appropriate illustration.
C. Adjust low flame setting for each burner. Follow the
instructions for burner low flame adjustment on page 7
to increase the simmer flame size.
Q
Q
JGD8348BDP
Left Rear (LR)
8,000
#55
.0520
Green
Left Front (LF)
8,000
#55
.0520
Green
Center Rear (CR)
10,000
#53
.0595
Brass
Center Front (CF)
10,000
#53
.0595
Brass
Right Rear (RR)
10,000
#53
.0595
Brass
Right Front (RF)
10,000
#53
.0595
Brass