Jenn-Air'sventilation system is designed to capture both cooking fumes and smoke
while grilling. If the system does not, these are some ducting installation situations to
check:
• 6" diameter round or 3 1/4" x 10" rectangular ducting should be used. Note: 5"
diameter round ducting may be used if the duet length is 10' or less.
• No more than three 90° elbows should be used. Distance between elbows should
be at least 18".
• RecommendedJenn-Airwallcapshouldbeused.
Make sure damper moves freely
when ventilation system is operating.
• There should be a minimumclearance of 6" for cooktop installed near a side wall.
If there is not an obvious improper installation, there may be a concealed problem such
as a pinched joint, obstruction in the pipe, etc. Installation is the resoonsibilitv of the
installer and questions should be addressed first by the installer. The installer should
very carefully check the ducting installation instructions.