Carrier 50TFQ008-012 Product Data page 24

Single-package standard efficiency rooftop heat pump units 50 hz
Table of Contents

Advertisement

Performance data (cont)
50TFQ008,009 (26.4 AND 29.9 kW)
Airflow
50
(L/s)
R/s
BkW
R/s
1100
8.7
0.42
10.1
1200
9.3
0.52
10.5
1300
9.8
0.54
11.0
1400
10.4
0.77
11.5
1500
11.0
0.92
12.0
1600
11.6 1.08
12.6
1700
12.2
1.26
13.1
LEGEND
BkW — Motor Brake (Output) Power (kW)
— Fan Wheel Speed, Revolutions per Second
R/s
NOTES:
1. Boldface indicates field-supplied drive required.
2.
indicates field-supplied motor and drive required.
3. Maximum usable output power (BkW) is 1.79 with standard
1.12-BkW motor. Extensive motor and electrical testing on these
50TFQ012 (35.2 kW)
Airflow
50
(L/s)
R/s
BkW
R/s
1300
8.4
0.37
8.8
0.46 10.0
1400
1500
9.2
0.55
10.4
1600
9.7
0.65
10.8
10.2 0.75
11.2
1700
10.6 0.87
11.7
1800
11.1
1.01
12.1
1900
11.6
1.16
12.5
2000
12.0
1.32
13.0
2100
12.5
1.50
13.4
2200
13.0
1.70
13.9
2300
LEGEND
BkW — Motor Brake (Output) Power (kW)
— Fan Wheel Speed, Revolutions per Second
R/s
NOTES:
1. Boldface indicates field-supplied drive required.
2.
indicates field-supplied motor and drive required.
3. Maximum usable output power (BkW) is 2.16 with standard
1.50-BkW motor. Extensive motor and electrical testing on these
24
FAN PERFORMANCE (SI) — VERTICAL DISCHARGE UNITS
100
150
200
BkW
R/s
BkW
R/s
0.59
11.1
0.75 12.2
0.69
11.6
0.87 12.6
0.81
12.1
1.01 13.0
0.94
12.6
1.16 13.5
1.10
13.0
1.33 13.9 1.56
1.28
13.5
1.50 14.4 1.76
1.48
14.0
1.70 14.9
100
150
200
BkW
R/s
BkW
R/s
9.6
0.51
10.8
0.61 11.7
0.59
11.1
0.71 12.0 0.82 12.9 0.93 13.7 1.04 14.5
11.5
0.81 12.4
0.68
0.79
11.8
0.93 12.8
0.91
12.2
1.06 13.1
1.05
12.6
1.20 13.5
1.19
13.0
1.35 13.9
1.35
13.4
1.52 14.3
1.53
13.8
1.70 14.6 1.88
1.71
14.3
1.91 15.1
1.91
14.7
2.13 15.5
External Static Pressure (Pa)
250
300
BkW
R/s
BkW
R/s
BkW
0.93 13.1
1.12
14.0 1.30
1.05 13.5 1.26 14.3 1.46
1.20 13.9 1.41
14.7 1.63
1.37
14.3
1.58
15.1
1.80
14.7
1.78
15.5
2.00
15.2
2.00
16.0
2.23
1.97
15.7
2.23
16.4
2.48
units ensures that the full brakepower range of the motor can be uti-
lized with confidence. Using your fan motors up to the brakepower
ratings shown will not result in nuisance tripping or premature motor
failure.
4. Use of field-supplied motor may affect wire sizing. Contact Carrier
representative to verify.
5. Values include losses for filters, unit casing, and wet coils.
6. Motor drive range is 10.33 to 14.67 r/s. All other r/s's will require a
field-supplied drive.
External Static Pressure (Pa)
250
300
BkW
R/s
BkW
R/s
BkW
0.69
12.6
0.81 13.3
0.90
0.94
13.2
1.06
14.0
1.19 14.8
1.07
13.6 1.19 14.4 1.33
1.20
13.9
1.34
14.7
1.48
1.35
14.3 1.51 15.0 1.65
1.52 14.7 1.68
15.4 1.84
1.69
15.0
1.86
15.8 2.04
16.1
2.25
15.4
2.07
2.09
15.8
2.29
16.5
2.48
2.31
16.2
2.52
units ensures that the full brakepower range of the motor can be uti-
lized with confidence. Using your fan motors up to the brakepower
ratings shown will not result in nuisance tripping or premature motor
failure.
4. Use of field-supplied motor may affect wire sizing. Contact Carrier
representative to verify.
5. Values include losses for filters, unit casing, and wet coils.
6. Motor drive range is 11.50 to 15.00 r/s. All other r/s's will require a
field-supplied drive.
350
400
R/s
BkW
R/s
BkW
R/s
14.8
1.51 15.7 1.77
16.4
15.1
1.66 15.9
1.88
16.7
15.5
1.84 16.2
1.98
16.9
15.9
2.04 16.6
2.27
17.3
16.3
2.25 17.0
2.50
16.7
2.47
350
400
R/s
BkW
R/s
BkW
R/s
14.3
1.05 15.1 1.27 15.9 1.48 16.7 1.67
1.17 15.4 1.35 16.2 1.56 16.8 1.75
1.26 15.6 1.44 16.4 1.62 17.1 1.83
15.1
1.46 15.8 1.59 16.5 1.72 17.3 1.91
15.4
1.63 16.1 1.76 16.7 1.89 17.4 2.04
15.7
1.80 16.4 1.95 17.1 2.10
16.1
1.99 16.8 2.14
17.4
16.5
2.21 17.1
2.36
17.7
16.8
2.43
450
500
BkW
R/s
BkW
2.02
17.2
2.35
2.14
17.4
2.44
2.29
17.6
2.56
2.51
450
500
BkW
R/s
BkW
17.7
2.24
2.31
18.0
2.46
2.53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

50tfq00850tfq00950tfq012

Table of Contents