'98
TIS
FIG. 6
2.
Once the tower front strip is slipped under the hlnge,
the part is possible to swing into place as shown in
FIG. 6.
3.
Secure the refrigerator and the lower front strip with
two screws:
One screw through the hinge, snd on the opposite
side one screw through the lower front strip. (FIG. 6).
STEP 2: Two screws Installed In the top frame.
The top decoration panel must be removed from the
refrigerator before the screws can be installed.
Open the upper door and gently push the tabs out of the
hole in the hinge with a flat blade screwdriver, (both
sides). See FIG. 7.
Carefully tilt the top decoration panel and lift up to
remove from top frame. Be careful not to damage the
circuit board and wires.
1
FIG. 7
tnstatt the two screws in the top frame, the holes are
accessible from underneath.
Seal the opening for the screws with aluminum tape.
Replace the top decoration panel. Be careful not to pinch
the wires behind the panel. Make sure the
back
into the holes in the hinge plate.
STEP 3: T w o screws Installed in the rear base.
See FIG. 8.
Failure to follow the sequence In securing refrigerator in
enclosure can cause leakage between the frame and
cabinet.
46 141 238393
tabs snap
MO
Hole for drain
water
ho
FIG. 8
Any space between the counter, storage area or ceiling
and top of the refrigerator greater than 1-1/2 inches
should be blocked. The heal produced at the rear of the
refrigerator will become trapped in thts space, making
the top of the refrigerator hot and reduce the efficiency
of the refrigerator.

Drain water hose

A hole must be drilled through flooring see FIG. 8.
The hole must be drilled in the cut out opening of the
base plate at the rear of the refrigerator. The installer
MUST maks sure that the hose does not kink when run
through the floor. Seal around the hose that goes
through the drilled hole. If a longer hose than supplied Is
required to get the water to drain outside of the vehicle,
the installer will have to supply the extra length of hose.
TESTING LP GAS SAFETY
SHUTOFF
The gas safety shut-off must be tested after the
refrigerator is connected to the LP gas supply.
To test the gas safety shut-off, proceed as follows:
1.
Start the refrigerator and switch to the GAS mode.
(see start up instructions).
Check that the gas flame Is lit and the GAS mode
2.
Indicator lamp (C) is on.
3.
Close the manual gas shut-off valve at the back of
the refrigerator. (See FIG. 1).
4.
Wait f or one minute. The CHECK indicator lamp (E)
should be on and the GAS mode indicator lamp (C)
should be off.
5.
Remove protection cover (see FIG. 1) and open the
manual gas shut-off valve. Do not change any button
positions on the control panel. Apply a non-corrosive
commercial bubble solution to the burner jet orifice.
6.
No bubbles should appear at the opening of the
burner jet orifice. The presence of bubbles indicates
a defective gas safety shut-off and service is re-
quired.
7.
If no bubbles were present at the burner jet orifice, it
should be rinsed with fresh water. Be careful not to
damage the burner jet orifice. Replace cover and
press the main power ON/OFF button (1) OFF and
back ON. Normal operation of the burner should
return. Allow the burner to operate for a minimum of
five minutes.