Use the RM-95 to monitor the input voltage
Location
Page 2,
Read data that corresponds to the input voltage.
Address 52.
This reference voltage will be used next.
Input Camera Shutoff Address Data
The camera shutdown point must be input as data.
1. Set the RM-95 to location Page d, Address 90.
2. Take the data reference number and put it in this address location.
3. Press the Pause button to save the information.
Input Battery Data
As the camera's battery voltage drops, the three shaded LCD battery
symbol inserts drop out to reveal an empty battery. A short time after the
third segment drops out, a flashing battery warning appears on the LCD
screen. These four battery voltage thresholds are inserted as data levels
at page d.
The data reference number from above is in hexadecimal. You must
convert that hexadecimal number to decimal, then add 5. Convert this
new decimal number back to hexadecimal and put that number into Ad-
dress 91.
1. Use the hexadecimal to decimal Conversion Table in the service manual
to change the reference data number at Page d Address 91 to a deci-
mal number. In the example given, hex number AE is looked up in the
chart as decimal 174. The conversion chart is under "Data Process" in
the table of contents.
AE
174
ref number
Decimal
2. In a similar process, add decimal number 23 instead of 5, convert it
back to hex and change the data in Page d, Address 92.
3. In a similar process, add decimal number 44 instead of 5, convert it
back to hex and change the data in Page d, Address 93.
4. In a similar process, add decimal number 55 instead of 5, convert it
back to hex and change the data in Page d, Address 94.
Purpose
179
b3
add 5
Convert to Hex
Name
D ref
D ref + decimal 5
D ref + 23
D ref + 44
D ref + 55
D ref (output)
measurement
5. Press the Pause button to save the information after each adjustment
(address change).
Sample Data
The following is data taken from a sample camera.
Hexadecimal (RM-95)
Address
Data
90
85
91
8A
92
9C
93
b1
94
bc
b3
Load
viii
Battery Symbol Page d, Address Locations
Page d,
Address
90
Camera shutdown point
91
Blinking battery warning
92
LCD battery segment 1
93
LCD battery segment 2
94
LCD battery segment 3
Page 2,
Read DC input voltage as
Address 52
data.
Sample Data at Page d
Decimal equivalent (service
manual chart)
133 (5.5Vdc)
133 + 5 = 138
133 + 23 = 156
133 + 44 = 177
133 + 55 = 188