Motion Sensitivity; Service; Disable System Setting Option - Bosch VSS7390/01T Installation Instructions Manual

Bosch vss7390/01t switcher installation instructions
Table of Contents

Advertisement

VSS7390/01T Switcher | Installation Manual | Chapter 2
FIELD OF
(Range 1: 1.33: 1.66 : 2: default is
1). Adjust the field of view using
VIEW
digital zoom in the camera to
ensure complete coverage of the
object within the viewing angle of
the camera lens.
MICROPHONE
Select the microphone ON/OFF.
This function will be disabled when
cameras are connected without a
microphone (e.g. covert cameras).
MOTION
Allows you to define the area size
for motion detection.
AREA
MOTION
Allows you to define the sensitivity
of motion detection.
SENSITIVITY
This enables you to detect objects
like a person running across the
motion area but will not raise an
alarm if there is a small movement
(detect humans but no birds).
DISPLAY
This allows you to view where the
motion has been detected by dis-
MOTION
playing a series of movement indi-
cators on the monitor screen.

2.4.8 Motion Sensitivity

M A I N M E N U
SYSTEM SETTINGS
INST ALLATION
S E T U P C A M E R A 1
MO T ION S EN S I T I VIT Y 1
LEVEL
MO T IO N IN DIC ATOR
RESET INDICATOR
LEVEL
Sets the level (the amount) of
motion detection.
MOTION
Displays the set level of motion
detection.
INDICATOR
RESET
Resets the motion detection indica-
tor to the current setting.
INDICATOR
Set motion alarm as follows:
1 Reset indicator.
2 Set level on minimum.
3 Walk through motion area (motion indicator indi-
cates level of motion).
4 Set level just below the level of motion indication.
Bosch Security Systems | 2003-06

2.4.9 Service

The SERVICE menu contains all items relevant for
servicing your observation system: resetting the system
to factory defaults and the internal diagnose.
M A I N M E N U
SYSTEM SETTINGS
S ERV ICE
SYSTEM DIAGNOSE
FACTOR Y DEFAULTS
SYSTEM
With this option you can obtain an
overview of the internal diagnose
DIAGNOSE
settings. (Consult the service man-
ual for more information).
FACTORY
With this option you can set the
complete system to the factory
DEFAULTS
defaults. All current settings will be
lost, (this will take a few seconds).
Language selector and Wizard
setup will be activated again.
M A I N M E N U
SYSTEM SETTINGS
SEVICE
FACT OR Y DEF A ULT S
CURRENT SETTINGS
WILL BE LOST
C ON TI NUE ?
N O

2.4.10 Disable System Setting Option

You can disable the system setting option, ensuring
operators do not make inadvertent system changes.
To menu lock the system settings option:
Switch the complete system off.
Switch the system on while keeping the PIP and PIP
Swap buttons pressed at the same time. Continue to
keep the buttons pressed until the start-up screen
appears.
System settings are removed from the main menu.
Note
Follow the same procedure to unlock the system settings
menu.
EN | 10
YE S

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents