INSTALLATION
NATURAL GAS - KIT #: 740-950 PROPANE - KIT # 740-952
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Natural Gas Conversion Kit 740-950 Contains:
Qty. Part #
Description
1
904-240
Burner Orifi ce #37 (Natural Gas)
1
918-034
Decal "Converted to 30,000 Btu"
1
918-148
Instruction Sheet
Propane Conversion Kit 740-952 Contains:
Qty. Part #
Description
1
904-390
Burner Orifi ce #52 (Propane)
1
918-149
Decal "Converted to 28,500 Btu"
1
918-148
Instruction Sheet
1) Shut off the gas supply.
2) Open the front door. Carefully remove the logs and lava rock. (Refer
to manual for more detailed instructions.)
3) Remove burner by removing 2 screws, sliding the burner to the left
and lift out. See diagram below.
Note: Use a magnetic type screwdriver if possible.
4) Remove Rear Log Bracket by removing 2 screws. See diagram
below.
32
CONVERSION KIT TO LOWER BTU RATING
5) Unscrew the 2 Rear Log Pins and move to the front hole position.
6) Reinstall Rear Log Bracket.
7) Remove burner orifi ce with a 1/2" wrench and discard.
Burner Orifi ce
8) Reinstall new burner orifi ce (NG stamped #37 or LP stamped #52)
and tighten.
9) Reverse steps 3) and 2).
10) Set aeration setting. See settings under aeration adjustment in this
manual.
®