LASER SAFETY PRECAUTIONS

Caution: These labels may be attached to the unit on the rear and inside to
inform that it contains a laser component. Use of controls or adjustments, or
performance of procedures other than those specified within the service or
instruction manual may result in hazardous radiation exposure.
CLASS 1 LASER PRODUCT
1. Service should only be performed by qualified personnel.
2. This equipment has been designed and manufactured to meet
international safety standards; it is the legal responsibility of the repairer to
ensure that these safety standards are maintained.
3. Any repairs must be made in accordance with the relevant safety
standards.
4. It is essential that safety and EMC critical components are replaced with
Cambridge Azur approved parts only.
NOTES ON HANDLING THE OPTICAL PICK-UP BLOCK OR BASE UNIT
The laser diode in the optical pick-up block may suffer electrostatic breakdown because of the
potential difference generated by the charged electrostatic load, etc. on clothing and the human
body.
During repair, pay attention to electrostatic breakdown and also use the procedure in the printed
matter which is included in the repair parts.
The flexible board is easily damaged and should be handled with care.
NOTES ON LASER DIODE EMISSION CHECK
The laser beam on this model is concerated so as to be focused on the disc reflective surface by
the objective lens in the optical pick-up block. Therefore, when checking the laser diode
emission, observe from more than 30cm away from the objective lens.
WARNING!