Specifications; Wiring Diagrams - Desa 40,000 Owner's Manual

H.s.i. series portable forced air heaters heater sizes: 40,000 55,000 60,000 70,000 110,000 115,000, 150,000 155,000 165,000 and 200,000 btu/hr models
Hide thumbs Also See for 40,000:
Table of Contents

Advertisement

SPECIFICATIONS

16

WIRING DIAGRAMS

SPECIFICATIONS
Model Size
Output Rating (Btu/Hr)
Fuel
Fuel Tank Capacity
(U.S. Gal./Liters)
Fuel Consumption
(Gal. Per Hr/Liters Per Hr)
Pump Pressure (psi)
Electric Requirements
Amperage (Normal Run)
Motor RPM
Hot Air Output (CFM)
Motor HP
Shipping Weight
(Approximate Pounds/Kilograms)
Heater Weight without Fuel
(Approximate Pounds/Kilograms)
* Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter maintenance. Use in extreme cold
temperatures may require nontoxic anti-icer additives.
WIRING DIAGRAMS
Photocell
Photocell
Ignitor
Motor Return
AC Neutral (L2)
120V (L1)
Motor
Ignitor
Figure 34 - Wiring Diagram without Thermostat (40/55/60/70/110/115/150/155/165 Models)
40
55/60
40,000
55,000
and 60,000
Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels*
3/11.3
5/18.9
.3/1.14
.44/1.67
3.0
3.4
120 V/60 HZ (Same All Models)
2.0
2.0
1725
1725
170
180
1/15
1/15
32/14.5
33/15
28/12.7
29/13.1
Blue
Photocell
Blue
White
Green
Motor
Red
Black
Yellow
For more information, visit www.desatech.com
For more information, visit www.desatech.com
70
110/115
70,000
110,000
and 115,000
5/18.9
9/34
.52/1.97
.85/3.00
4.7
5.3
2.8
3.6
3440
3400
360
490
1/8
1/5
35/15.9
54/24.5
31/14
46/21
White
Green
Ignitor
150/155
165
150,000
165,000
and 155,000
13.5/51
13.5/51
1.14/4.31
1.2/4.54
5.4
5.6
3.6
3.6
3400
3400
550
575
1/5
1/5
63/28.6
65/29.5
54/24.5
55/25
200
200,000
13.5/51
1.4/5.3
6.2
3.6
3400
600
1/4
77/35
66/30
108871

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents