Comtech EF Data MBT-4000 Installation And Operation Manual page 65

Multi-band transceiver system
Hide thumbs Also See for MBT-4000:
Table of Contents

Advertisement

MBT-4000 Multi-Band Transceiver System
Remote Control
Command
Valid on
Parameter
(Instruction
Type
Code and
BDC, or
qualifier)
Serial Number N/A
All
Retrieve
N/A
MBT
Utility Status
Remote Baud
SBR=xxxx
MBT
Rate
Summary
N/A
All
Fault Status
Remote
SPA=xxxx
MBT
Address
Arguments
MBT,
for Command
(Note that all arguments are ASCII numeric codes – i.e.,
or Response
BUC
to Query
9 bytes,
Query only.
numeric
Used to Query the units 9 digit serial number.
000000000 to
Slave returns its S/N, in the form xxxxxxxxx.
999999999
Example: RSN=000000165
24 bytes
Query only.
alphanumeric
Used to Query the utility status of the MBT-4000 base unit..
Example:
<0001/RUS={cr}
>0001/RUS={cr}{lf}
ADR=0001{cr}
BDR=9600{cr}{lf}
4 bytes,
Command or Query.
Set remote baud rate as follows:
9600 = 9600 baud
19K2 = 19200 baud
N/A
Query only.
Used to Query the status of the Summary Fault Relay, where:
0=OK
1=FT
Example: SFS?
4 byte,
Command or Query.
numeric
Set Physical Address-between 0001 to 9999.
Resolution 0001
Example: SPA=0412
Description of Arguments
ASCII codes between 48 and 57)
A–21
Revision 4
MN/MBT4000.IOM
Response to
Query
Command
(Instruction
(Target to
Code and
Controller)
qualifier)
N/A
RSN?
N/A
RUS?
SBR= (message OK)
SBR?
SBR? (received OK,
but invalid arguments
found)
SBR! (Command not
accepted by BUC
and BDC sub-units.)
N/A
SFS?
SPA= (message OK)
SPA?
SPA? (received OK,
but invalid arguments
found)
SPA! (Command not
accepted by BUC
and BDC sub-units.)
Response to
Query
(Target to
Controller)
RSN= x....x
(see description
for details of
arguments)
RUS=x....x
(see description
for details of
arguments)
SBR=xxxx
(same format as
command
arguments)
SFS=x
(see description
for details of
arguments)
SPA=xxxx
(same format as
command
arguments)

Advertisement

Table of Contents
loading

Table of Contents