Bin Control; Gear Motor - Cornelius WCC1401-A Series Service Manual

Cornelius continuous flow icemaker
Hide thumbs Also See for WCC1401-A Series:
Table of Contents

Advertisement

Continuous Flow Icemaker Service Manual
B
C
IN
ONTROL
The type of bin control used on all WCC and WCF Models is an electronic control. The control is supplied with
power to terminals X1 and X2. Terminals X3 and X4 are a normally closed switch which open when the thermostat
sensor bulb senses ice. The WCC1401-A/WCF1401-A uses 2 controls, terminals X1 and X2 are connected in
parallel and terminals X3 and X4 are connected in series.
The sensing bulbs are located in a 5/16" stainless steel tube which hangs from the dispense tray covers down
through the center of the drop tube.
To test the switch, start the icemaker and block the outlet tube, about ½ full the icemaker should shut off. When the
tube is cleared the icemaker should restart within 5 min.
The Bin controls are in electrical series with the coil on the antifreeze relay along with the low water safety.
The controls are held in place inside the electrical box by 4 screws. The control bulbs are in the drop tubes. They
can be removed by pulling the cable located on the top of the dispense tray cover. When replacing the sensor make
sure the bulb is inserted to the bottom of the thermostat well.
G
M
EAR
OTOR
The gear motors are equipped with a start relay and a manual reset overload.
When current is applied, the relay energizes and completes the circuit to the start winding. The motor reaches a
predetermined speed and the relay drops out, disconnecting the start winding. The run winding remains in the
circuit as long as current is applied.
The purpose of the overload is to automatically shut off the motor in the event of a mechanical bind of the
transmission, an overload condition within the evaporator or an electrical malfunction. It does this by sensing
amperage draw. If the motor stalls the start relay would energize and stay energized. The amperage would surge 5
to 6 times greater than normal draw. In this event the overload would shut off the transmission in 4 to 8 seconds.
If the motor is subjected to abnormal load, but does not reach stall condition, the overload will react, but over a
greater period of time. The reaction time depends upon the amperage to which it is subjected.
The overloads to each motor are connected in series; if either overload trips both gear motors and the liquid line
solenoid are shut off.
Publication Number: 630460324SER