Item
Condition
5.Max deviation TEST CH: Center
Adjust
[Wide]
AG:1kHz/150mV
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
6.VOX 1
TEST CH:Center
Writing
AG:1KHz/45mV
7.QT deviation TEST CH: Center
Adjust
[Wide]
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
PTT:ON
8.DQT deviation TEST CH: Center
Adjust
[Wide]
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
9.DTMF deviation TEST CH:Center
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
10.MSK deviation TEST CH: Center
Adjust
[Wide]
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
18
ADJUSTMENT
Test equipment
Power meter
Low
Deviation meter
High
Oscilloscope
(3 points)
AG
AF VTVM
Low
High
(3 points)
Low
High
(3 points)
Low
High
(3 points)
Measurement
Terminal
ANT
Programming
SP/MIC connector
Software:KPG-87D (According to
ANT
Programming
Software:KPG-87D
Adjustment
Parts
Method
4.2kHz
the larger +,–)
2.2kHz
(According to
the larger +,–)
0.75kHz
0.38kHz
0.75kHz
0.38kHz
3.0kHz
1.5kHz
3.1kHz
1.5kHz
Specifications/
Remark
±80Hz
±80Hz
±40Hz
±40Hz
±40Hz
±40Hz
±100Hz
±100Hz
±100Hz
±100Hz