CLEARANCES

CLEARANCES TO COMBUSTIBLES
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other
than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed
on a metal, wood or noncombustible material panel extending full width and depth of
the appliance.
Mantel Shelf Chart (Minimum Height)
Ref. Mantel Depth
V
10" (254mm)
W
8" (203mm)
X
6" (152mm)
Y
4" (101mm)
Z
2" (50mm)
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than
it is considered a mantel and must meet the mantel requirements listed in this manual.
14
Ref. Height Above Louvres
A
12" (305mm)
B
10" (254mm)
C
8" (203mm)
D
6" (152mm)
E
4" (101mm)
� � � � �
Figure 11 - Clearances