Siemens CF62 Leopard Service Manual

Hide thumbs Also See for CF62 Leopard:

Advertisement

Quick Links

SIEMENS
CF62 Level 2 Service Manual
BE INSPIRED
CF62 Leopard
Clean & distinctive design
SSMC MD CCQ
Copyright © Siemens Mobile
1 of 42
All rights reserved
Internal Service Use Only
Siemenes Shanghai Technical Support Center

Advertisement

Table of Contents
loading

Summary of Contents for Siemens CF62 Leopard

  • Page 1 SIEMENS CF62 Level 2 Service Manual BE INSPIRED CF62 Leopard Clean & distinctive design SSMC MD CCQ Copyright © Siemens Mobile 1 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 2: Table Of Contents

    3 Accessories……………………………………………………………………….. 11 4 Unit Description CF62 Leopard .............……12 4.1 Assembling concept for the customer ..........12 4.2 Interface CF62 Leopard to accessories ……………………...…………. 12 4.3 Exploded view of CF62 Leopard ………………………………………… 13 4.4 Handset parts and defined service parts …………………………………15 4.5 PCB top-side ………………………………………………………………...
  • Page 3: Cellular Communication

    Cells are often represented by hexagons (see figure 1.1.). Figure 1.1 CELLULAR COVERAGE REPRESENTATION SSMC MD CCQ Copyright © Siemens Mobile 3 of 42 All rights reserved Internal Service Use Only...
  • Page 4: Gsm Network Architecture

    An option the network operator can use to enforce security. With this feature the network can identify defective or stolen mobile that may not be used in the network. SSMC MD CCQ Copyright © Siemens Mobile 4 of 42 All rights reserved...
  • Page 5: Subscriber Identity Module

    (Consult the operator for more Information about the PIN 2). A code (PUK) is provided for unlocking the SIM card if the SIM card is blocked SSMC MD CCQ Copyright © Siemens Mobile 5 of 42 All rights reserved...
  • Page 6: Wap ( Wireless Application Protocol )

    WAP Internet access via the CF62 is possible with the inclusion of Wireless Application Protocol (WAP) browser 1.2.1. SSMC MD CCQ Copyright © Siemens Mobile 6 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 7: Gprs (General Packet Radio Service)

    1 physical channel for signaling, 4 physical channels for Circuit switched and 3 physical channels for Packet switched. SSMC MD CCQ Copyright © Siemens Mobile 7 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 8: K-Java Application

    MIDP 1.0, CLDC 1.0 As SL45i, including performance optimizations from SL45i-Infusio. ‘OEM extensions’ Proprietary API extension as SL45i. Including ‘Siemens Game API’. HTTP API over GPRS Sl45i: only CSD SSMC MD CCQ Copyright © Siemens Mobile 8 of 42...
  • Page 9: Cf62 Technical Information

    • two function keys (SEND, END) • ON/OFF key combined with the END key; the symbol inside O) is used as a symbol for ON/OFF. SSMC MD CCQ Copyright © Siemens Mobile 9 of 42 All rights reserved Internal Service Use Only...
  • Page 10: Comparison With Previous Products

    Performance in 0 dB @ 1900 MHz -1,5 dB @ 1900MHz comparison to C56 Half Rate Enhanced Full Rate SSMC MD CCQ Copyright © Siemens Mobile 10 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 11: Accessories

    L36880-N5601-A149 Tour Case FCT-650 C60/A60/CF62/CX65/CXT65 L36880-N6501-A102 Data Cable USB DCA-540 SX1/CX65/CXT65/CXV65/CF62 L36880-S5601-A800 Data Cable Serial without Blister Packaging SSMC MD CCQ Copyright © Siemens Mobile 11 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 12: Unit Description Cf62 Leopard

    CF62 Level 2 Service Manual 4. Unit Description CF62 Leopard The CF62 Leopard is designed as a clamshell with non-exchangeable housing. The lift cover,base lower and battery cover are lacquered parts (1shot-molding;1color). Base upper assembly is composed of base upper and light loop by ultra-sonic welding (The base upper is lacquered 1shot-molding part.The light loop is a 2shot-molding part by light...
  • Page 13: Exploded View Of Cf62 Leopard

    SIEMENS CF62 Level 2 Service Manual 4.3 exploded view of CF62 Leopard • Assembly in total with lift assembly SSMC MD CCQ Copyright © Siemens Mobile 13 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 14 LCD Cushion Magnet Screw Lift cover LCD module Hinge Vibra FPCB LCD Cushion main Display lens main B SSMC MD CCQ Copyright © Siemens Mobile 14 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 15: Handset Parts And Defined Service Parts

    C39158-A120-C342 Level1 Magnet (V39190-F105-F751), Lift frame (C39158-A120-B21), Lift frame assembly C39158-A120-B21 Display lens main A (C39158-A120-B301) (C39158-A120-C341) (C39158-A120-C35). SSMC MD CCQ Copyright © Siemens Mobile 15 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 16: Pcb Top-Side

    Only for Lift part Screw 1,6x4,5 CF62 C39158-A120-C90 assembly PCB (Main board) Level2 4.5 PCB top-side 4.6 PCB bottom-side SSMC MD CCQ Copyright © Siemens Mobile 16 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 17: Disassembly Of Cf62 Leopard

    SIEMENS CF62 Level 2 Service Manual Disassembly of CF62 Leopard ESD concept; the internal circuits will be more susceptible to ESD because of the use of exchangeable housing. The construction of the internal block must be/is designed, in the best possible way, to protect the circuit against sparks.
  • Page 18 Step Step Release the screw cover. Remove the three Base lower screws in the corners with the screwdriver. SSMC MD CCQ Copyright © Siemens Mobile 18 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 19 (Main board) Assembly. Step Remove the PCB Assembly by holding it of both in the middle and lifting it straight up. SSMC MD CCQ Copyright © Siemens Mobile 19 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 20 To separate the Lift part assembly from the Base seen after disassembled. upper assembly, push the hinge catch inwards with a pair of special driver. SSMC MD CCQ Copyright © Siemens Mobile 20 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 21 Remove the Hinge and the Vibra from the Lift Remove the LCD module from the Lift frame cover assembly. assembly. SSMC MD CCQ Copyright © Siemens Mobile 21 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 22 Fully disassembled the Lift part assembly. Remove the LCD Cushion main from the Lift frame assembly. Step Fully disassembled CF62 SSMC MD CCQ Copyright © Siemens Mobile 22 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 23: Assembly Of Cf62 Leopard

    SIEMENS CF62 Level 2 Service Manual Assembly of CF62 Leopard Step 1: For the reassembly of the CF62 Lift part assembly, reverse the disassembly procedures Step 14 from J to A. Reassembled Lift part assembly as shown. Set torque to 16 Ncm.
  • Page 24 Place the PCB Assembly onto the Base upper assembly. The three pins (marked with arrows) align the PCB Assembly in its correct place. SSMC MD CCQ Copyright © Siemens Mobile 24 of 42 All rights reserved Internal Service Use Only...
  • Page 25 Base upper assembly. Check that the Base lower assembly is ok and all the components are in their places. SSMC MD CCQ Copyright © Siemens Mobile 25 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 26 Put the battery into the Base lower as shown. locked. Step 11: Unfold the Lift part press ON/OFF key as shown. SSMC MD CCQ Copyright © Siemens Mobile 26 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 27: Mobile Software Programming

    - Software update to actual version and appropriate language group - Programming of customer specific initialization. Include mapping and FFS. FIGURE 7.1 CF62 SERIES SOFTWARE PROGRAMMING SETUP SSMC MD CCQ Copyright © Siemens Mobile 27 of 42 All rights reserved Internal Service Use Only...
  • Page 28: Mobile Software Updating

    L36880-N9241-A200 cable and mobile connection cable IBM Compatible PC – Pentium TABLE 7.1 EQUIPMENT LIST FOR SOFTWARE PROGRAMMING. SSMC MD CCQ Copyright © Siemens Mobile 28 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 29: Flow Chart For S/W Upgrading

    SIEMENS CF62 Level 2 Service Manual 7.3 Flow chart for S/W upgrading SSMC MD CCQ Copyright © Siemens Mobile 29 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 30: Siemens Service Equipment User Manual

    2. Sets, which pass the test, will be good enough to return to customer. Starting from the P35 Series, Siemens will introduce a simpler and faster testing platform for testing a repaired Siemens mobile phone. The testing platforms are either base on R&S CMD 53/55 , CTS30/55 or CMU200GSM test set.
  • Page 31: Jpics (Java Based Product Information Controlling System)

    General mobile information • Generate PINCODE • Generate SIMLOCK-UNLOCK-Code • Print IMEI labels • Lock, Unlock and Test the BF-Bus SSMC MD CCQ Copyright © Siemens Mobile 31 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 32 Kamp-Lintfort. In case of any questions or requests concerning chip cards or administration of the databases please ask your responsible Siemens Customer Care Manager. SSMC MD CCQ Copyright © Siemens Mobile 32 of 42 All rights reserved...
  • Page 33 1. The JPICS Installation-CD 2. A chip card. Chip cards can be ordered via your responsible Customer Care Manager within Siemens. 3. A supported chip card reader (Smarty or Siemens B1) in order to access your chip card. Remark: We recommend using Siemens B1 reader. Similar device to B1 is Cardman 9010.
  • Page 34 • The user must be given the authorization to obtain Simlock Unlock- Codes for the variant of the operator to which the mobile was delivered last time. SSMC MD CCQ Copyright © Siemens Mobile 34 of 42 All rights reserved...
  • Page 35 Printing IMEI label The module “Print IMEI label” offers the possibility to re-print IMEI labels for mobiles again. SSMC MD CCQ Copyright © Siemens Mobile 35 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 36: International Mobile Equipment Identity, Imei

    Re-use of IMEI label is possible by using a hair-dryer to remove the IMEI label. On this IMEI label, Siemens has also includes the date code for production or service, which conforms to the industrial standard DIN EN 60062. The date code comprises of 2 characters: first character denotes the Year and the second character denotes the Month.
  • Page 37: General Testing Information

    The technical instruction for testing GSM mobile phones is to ensure the best repair quality. Validity This procedure is to apply for all from Siemens AG authorized level 2 up to 2.5e workshops. Procedure All following checks and measurements have to be carried out in an ESD protected environment and with ESD protected equipment/tools.
  • Page 38 Use a Test SIM. Skip GSM 900/GSM1800 or GSM1900 test cases if not performed by the mobile phone. SSMC MD CCQ Copyright © Siemens Mobile 38 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 39 SIEMENS CF62 Level 2 Service Manual SSMC MD CCQ Copyright © Siemens Mobile 39 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 40 SIEMENS CF62 Level 2 Service Manual SSMC MD CCQ Copyright © Siemens Mobile 40 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 41: Annex 1

    Test SIM Card from the company “T-D1” Pin 1 number: 1234 PUK1 : 76543210 Pin 2 number: 5678 PUK 2 : 98765432 SSMC MD CCQ Copyright © Siemens Mobile 41 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...
  • Page 42: Annex 2

    SIEMENS CF62 Level 2 Service Manual Annex 2 Battery Date Code overview SSMC MD CCQ Copyright © Siemens Mobile 42 of 42 All rights reserved Internal Service Use Only Siemenes Shanghai Technical Support Center...