Mitsubishi PKA-RP·HAL Operation Manual

Pka-rp·hal, pca-rp·kaq, pca-rp·haq, psa-rp·ga series indoor unit
Hide thumbs Also See for PKA-RP·HAL:

Advertisement

Air-Conditioners

Indoor unit

PKA-RP·HAL
PCA-RP·KAQ
PCA-RP·HAQ
PSA-RP·GA
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.
MANUAL DE INSTRUCCIONES
garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro
della stessa.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a
unidade de ar condicionado.
DRIFTSMANUAL
Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug.
DRIFTSMANUAL
Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L'UTENTE
PARA O UTILIZADOR
TIL BRUGER
FÖR ANVÄNDAREN
English
Deutsch
Français
Nederlands
Español
Italiano
Português
Dansk
Svenska
Türkçe

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi PKA-RP·HAL

  • Page 1: Indoor Unit

    Air-Conditioners Indoor unit PKA-RP·HAL PCA-RP·KAQ PCA-RP·HAQ PSA-RP·GA OPERATION MANUAL FOR USER English For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Deutsch Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2: Table Of Contents

    ......... 20 Note Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste.
  • Page 3: Parts Names

    Indoor Unit PKA-RP·HAL PCA-RP·KAQ PCA-RP·HAQ PSA-RP·GA Fan speed 3 speeds + Auto 4 speeds + Auto 2 speeds 2 speeds Vane Auto with swing Auto with swing Manual Manual Louver Manual Manual Manual Auto with swing Filter Normal Long-life Long-life Filter cleaning indication 100 hr 2,500 hr...
  • Page 4: Operation Section

    Display Section Displayed when the remote controller sensor is used. Day-of-Week For purposes of this explanation, Shows the current day of the week. all parts of the display are shown. During actual operation, only the relevant items will be displayed. Shows the current time, unless the simple or Auto Off Indicates that remote controller but- timer is set.
  • Page 5 Transmission area Transmission indicator Remote controller display Timer indicator *For explanation purposes, all of the items that appear in the display are shown. *All items are displayed when the Reset but- ton is pressed. Operation areas ON/OFF button Set Temperature buttons Fan Speed button (Changes fan speed) Timer Off button Timer On button...
  • Page 6: Setting The Day Of The Week And Time

    <Screen Types> Function Selection of remote For details on setting the language for the remote controller display, refer Set Day/Time controller to section 8. Function Selection. TIME SUN The initial language setting is English. Function Selection of remote controller: Set the functions and ranges available to the remote controller (timer functions, operating restrictions, etc.) Standard Control Screens...
  • Page 7 5. Operation Press the operation mode ( ) button and select the opera- tion mode Press button to set the desired temperature. The selected temperature is displayed Cooling mode Drying mode Fan mode Press button to set the desired temperature. Heating mode <Only heat pump type>...
  • Page 8: Timer

    5. Operation as necessary. To run the ventilator together with the indoor unit: • Each press changes the direction. The current direction is shown at . Press the ON/OFF button • The change sequence and the available settings are as follows. •...
  • Page 9 2. Press the Timer Menu button , so that the “Set Up” appears on the screen (at ). (Note that each press of the button toggles the display between “Set Up” and “Monitor”.) Timer Settings 3. Press the Timer On/Off (Set Day) button to set the day.
  • Page 10 Press the Timer On/Off button so that the timer setting no longer ap- Timer Setting pears on the screen (at Action (On or Off) AFTER * “— —” is displayed if there is no setting. SIMPLE SIMPLE 1. Be sure that you are at a standard control screen, and that the simple timer indicator is visible in the display (at When something other than the Simple Timer is displayed, set it to SIMPLE TIMER using the function selection of remote controller (see...
  • Page 11 Hold down the Timer On/Off button so that “Timer This timer begins countdown when the air conditioner starts and shuts Off” appears (at ) and the timer value (at ) disappears. the air conditioner off when the set time has elapsed. Available settings run from 30 minutes to 4 hours in 30-minute intervals.
  • Page 12: Other Functions

    7. Other Functions <How to Lock the Buttons> 1. While holding down the Filter button , press and hold down the ON/ OFF button for 2 seconds. The “Locked” indication appears on the If you wish, you can lock the remote controller buttons. You can use screen (at ), indicating that the lock is now engaged.
  • Page 13: Function Selection

    8. Function Selection The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when needed. Item 1 Item 2 Item 3 (Setting content) 1. Change Language Language setting to display •...
  • Page 14 8. Function Selection Normal display (Display when the air conditioner is not running) Setting language (English) Hold down the button and press the button for 2 seconds. Hold down the button and press the button for 2 seconds. Press the operation mode button. Press the TIMER MENU button.
  • Page 15 8. Function Selection [Detailed setting] [4]-3 Mode selection setting [4]-1 CHANGE LANGUAGE setting (1) Remote controller main/sub setting The language that appears on the dot display can be selected. • To switch the setting, press the [ ON/OFF] button • Press the [ MENU] button to change the language.
  • Page 16 8. Function Selection [Dot display table] Selecting language English German Spanish Russian Italian Chinese French Japanese Waiting for start-up Operation mode Cool Heat Auto Auto(Cool) Auto(Heat) Ventilation Stand by (Hot adjust) Defrost Set temperature Fan speed Not use button Check (Error) Test run Self check Unit function selection...
  • Page 17: Emergency Operation For Wireless Remote-Controller

    Starting operation • To operate the cooling mode, press the button for more than 2 seconds. • To operate the heating mode, press the button for more than 2 seconds. Stopping operation • To stop operation, press the button or the button for more than 2 seconds.
  • Page 18 PCA-RP·KAQ PCA-RP·HAQ Open the intake grille. into the stopper. Filter Intake Grille Knob Stopper side (inside) and then slide them in the direction of to remove. Optional parts: PAC-SG38KF (12 pieces) Note: Handle Filter element PSA-RP·GA • Protective goods such as a rubber glove •...
  • Page 19: Trouble Shooting

    Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. Check the temperature adjustment and adjust the set temperature. Make sure that there is plenty of space around the outdoor unit. Is the indoor unit air intake or outlet blocked? Has a door or window been left open? When heating operation starts, warm air does not blow from the indoor...
  • Page 20 Having trouble? Here is the solution. (Unit is operating normally.) Draining water or motor rotation sound is heard. When cooling operation stops, the drain pump operates and then stops. Wait approximately 3 minutes. The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than High sound Low sound...
  • Page 21 Model PSA-RP71GA PSA-RP100GA PSA-RP125GA PSA-RP140GA Power source(voltage <V>/Frequency<Hz>) ~/N 230/50 0.15/0.15 0.24/0.24 0.28/0.28 0.36/0.36 Rated Input(Indoor only) <kW> 0.66/0.66 1.06/1.06 1.23/1.23 1.59/1.59 Rated Current(Indoor only) <A> Heater <kW> Dimension(Height) <mm> 1900 Dimension(Width) <mm> Dimension(Depth) <mm> /min> 15-18 24-31 26-33 27-35 Noise level(Low-High) <dB>...
  • Page 22 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN RG79D719H01 Printed in Japan...

Table of Contents