Specifications - Invacare CareGuard CG9701 Brochure

Invacare corporation therapeutic support surfaces brochure
Hide thumbs Also See for CareGuard CG9701:

Advertisement

T
he Invacare
®
Group I Therapeutic Support Surfaces are designed to aid in the prevention and
treatment of pressure ulcers. Three types of modalities allow you to choose the right product for
the individual user. Product types include an alternating pressure pad system, gel overlay and a foam
mattress replacement. All of these products are simple to use and easy to maintain.

Specifications

Model no.
Weight
Length
CG10180
19 lb.
80"
CGGFMO
55 lb.
76"
Pump: 3.5 lb. 10"
CG9701
Pad: 4.6 lb.
118"
* For manufacturer's defects
®
Invacare
CareGuard
Foam Mattress
Model no. CG10180
Torso section of top layer anatomically sculptured for body conformity
Head and heel section of top layer constructed of softer, pressure absorbing
foam
Multiple layers of foam combine to provide the maximum pressure
reduction and durability - 1.85 lb., 29 ILD head and heel top layer, 1.8 lb.,
36 ILD torso top layer and 46 ILD bottom layer
Reversible head-to-foot with contour cuts to reduce shear
Articulation cuts on bottom layer facilitate gatching
Anti-microbial waterproof cover with a 70 denier top to reduce friction
Non-slip bottom cover provides secure positioning on bed sleep surface
Foam meets California Technical Bulletin #117 for fire retardancy and mattress
cover meets 16 CFR Part 1632, California Technical Bulletin #106
Designed to meet EO184
Does not contain latex
®
Invacare
CareGuard
Model no. CGGFMO
Four large 2" thick gel bladders inside polyurethane foam
Reversible for increased service life
Durable aggressive base material with strong elastic corner securing straps
reduce overlay movement
Vapor permeable waterproof cover with low friction and shear (Do not
machine wash)
Meets California Technical Bulletin #117
Designed to meet EO185
Does not contain latex
®
Invacare
CareGuard
Pressure Pad System
Model no. CG9701
Advanced pump technology alternately inflates and deflates air cells
Variable pressure setting for added patient comfort
Pump can be mounted on the bed with built-in bracket
Pad meets California Technical Bulletin #116
Designed to meet EO180
Does not contain latex
Width
Thickness
Power
35"
5"
n/a
34"
3.5"
n/a
6"
4"
115V, 160 HZ
34"
2.5"
n/a
101 Home Care
Gel Foam Mattress Overlay
APP Alternating
Code Approval
Weight Capacity
Limited Warranty
n/a
250 lb.
2 years
n/a
250 lb.
6 months
UL-1431
2 years
n/a
250 lb.
30 days
Invacare Corporation
www.invacare.com
USA
One Invacare Way
Elyria, Ohio
44035-4190
(800) 333-6900
Canada
570 Matheson Blvd. E
Unit 8
Mississauga, Ontario
L4Z 4G4 Canada
(800) 668-5324
Invacare is a registered
trademark and Yes, you
can., the blue medallion
design and CareGuard
are trademarks of
Invacare Corporation.
Specifications are subject
to change without
notification.
© 2003
Invacare Corporation
Form No. 00 -307
Rev. 12/03
''Invacare says 'Yes, you can
and I couldn't have said it
better myself.''
*
,'

Advertisement

loading

This manual is also suitable for:

Careguard cggfmoCareguard cg10180