Quadra-Fire 7100FP-BK-B Owner's Manual page 23

Epa certified woodburning fireplace
Hide thumbs Also See for 7100FP-BK-B:
Table of Contents

Advertisement

Figure 4.14 Disconnect Air Chamber Cover
- Remove two screws from timer linkage upper arm.
Be careful NOT TO DROP arm in bottom of fireplace.
See Figure 4.15
Move arm left
Figure 4.15 Remove Upper Arm
• Remove two screws from timer mounting plate
(Figure 4.16). Place your hand into the access door
(Figure 4.17) in the floor of the fireplace. Let the timer
assembly and plate drop down and rotate it up through
the access door. You will be looking at the back side of
the assembly. See Figure 4.18.
Timer Plate
Figure 4.16 Remove Screws from Timer Mounting Plate
Remove 2
screws
Be careful not to
drop Linkage Arm
down into fireplace
Quadra-Fire • 7100 FP Owner's Manual • 433-3600 • Rev G • 06/25/14
Figure 4.17 Hand in Access Door
Arm must be in this position
when re-installing
Rotate assembly up and
out through access door
Figure 4.18 Removing Timer Assembly
• Remove old air chamber cover. Place the cover under
the bottom of the firebox. Using a 7/16 wrench attach
the two 1/4-20 bolts as shown in Figure 4.19.
• If installing a new timer, skip to 4.B.7 Timer Removal
& Replacement, install timer, return to here.
• Insert the new timer assembly into the access door
with the back side towards you. Please note the
correct position of the linkage lower arm in Figure
4.18.
Air Chamber Cover
Attach with 1/4-20 bolts
Figure 4.19 Install Control Box
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

7100fp-gd-7100fp-nl-b7100fp-gd-b7100fp-nl-b

Table of Contents