Jumper Settings
To ensure correct system configuration, the following section describes how to set
the jumpers to enable/disable or change functions. For jumper descriptions, please
refer to the table below
Label
JP1
JP2
JP3
JP4
JP5
JP6
JP7
JP8
JP9
Table 4 JP2 Backlight & Panel Power Selection
KEMX-2030 User's Manual
.
Table 2 Jumper List
Function
Backlight Enable Selection
Backlight & Panel Power Selection
Clear CMOS Selection
COM1 Signal / Power Selection
COM2 Signal / Power Selection
COM3 Signal / Power Selection
COM4 Signal / Power Selection
For Quanmax internal test only
Power Mode Selection
Table 3 JP1 Backlight Enable Selection
Jumper
1-2
2-3
Pitch:2.0mm [YIMTEX 3291*03SAGR(6T)]
Jumper
Setting
1
2
Pitch 2.54mm [YIMTEX 3362*03SAGR]
Table 5 JP3 Clear CMOS Selection
Jumper
Open
Short
Pitch:2.54mm [YIMTEX 3321*02SAGR(6T)]
Status
Active High (Default)
Active Low
1-3
Backlight Power = +12V (Default)
3-5
Backlight Power = +5V
2-4
Panel Power = +3.3V (Default)
4-6
Panel Power = +5V
Status
Normal Operation (Default)
Clear CMOS
22
Chapter 2
Status