OPERATING PROCEDURE
9. Remove the compressor
(1) Remove the top panel, front cover, service panel.
(2) Remove the inside and outside connection electric wire,
next remove the back panel.
(3) Remove the inverter assembly.
(4) Can have the service of compression, 4-way and other
refrigerant circuit..
(5) Remove then the part (four places) which welds it when
you leave 4-way. (Photo 9)
Photo 9
Welded part
31