Troubleshooting - JVC AV-2100QE Service Manual

Table of Contents

Advertisement

5.1
SELF CHECK FUNCTIONS
5.1.1 OUTLINE
This model has self check functions given below. When an abnormality has been detected, the SUB POWER is turned off and POWER
LED flashes to inform of the failure. An abnormality is detected by the signal input state of the control line connected to the microcom-
puter.
5.1.2 SELF CHECK ITEMS
Check item
B1 over-current protection
CRT neck broken protection
5.1.3 SELF CHECK INDICATING FUNCTION
When an abnormality has been detected at about 5 seconds af-
ter the power was turned on, the SUB POWER is turned off im-
mediately and the POWER LED flashes.
[ INDICATION BY THE POWER LED]
B1 over-current protection / CRT neck broken protection
1-28 (No.YA552)
SECTION 5

TROUBLESHOOTING

Details of detection
An over-current on the low B1
line is detected.
Operation of CRT neck protec-
tion circuit.
Item
Method of detection
The main microcomputer de-
tects the possible abnormality at
24-msec. intervals and judges
the results in every 16 time. Of
the 16 times, if NG is detected
more than 9 times, it is judged
that there is an abnormality.
After about
5 seconds
Start of
Power on
Port
detection
LED flashing intervals
0.3 seconds
State of abnormality
When an abnormality has been
detected, the SUB-POWER is
turned off. While the SUB-POW-
ER is being turned off, the
POWER key on the remote con-
trol unit is not operational until
the power cord is disconnected
and connected again.
Detection of
an abnormality
Flashing LED
SUB-POWER OFF

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Av-21qmg7/gAv-21qmg7/sAv-21qmg7b/gAv-21q17Av-21q17/l

Table of Contents