EMERGENCY AND TEST OPERATION
Emergency Operation
Use this operation only when the remote controller is out of order or lost.
•
When the emergency operation switch is pressed, beep starts once, which
•
means the start of this operation.
In this operation, the system automatically selects the operation modes, cooling
•
(or heating when available) according to the room temperature, as follows.
Operation
Temperature
mode
ABOVE 23°C
COOLING
BELOW 23°C
HEATING
It is not possible to operate in dry mode.
•
Test Operation
Test operation switch is same as emergency one.
Use this operation only for testing the performance of the machine in
•
the condition where the room temperature is less than 16°C.
Continue to press the test operation switch for more than 5 seconds.
•
After you hear twice beep, release your finger from the switch
: the cooling operation starts with the air flow speed "HI."
If the test operation switch is pressed more than 10 seconds, it doesn't
•
work.
After 30 minutes, test operation ends automatically.
•
HOW TO RELEASE EMERGENCY AND TEST OPERATION
In case of releasing during those operations, you can either push emergency operation switch once more or
•
apply operation using remote control.
You will hear a beep sound and emergency/ test operation is released.
If you release the operation by remote control, operation will continue as setting of the remote control
•
automatically.
INTERFERENCE PREVENTION OF SIGNALS FROM THE REMOTE CONTROLLER
When two indoor units used in the same room, interference of the signals may happen. To avoid this, alternative
signal model B can be selected by the following. (Ex-factory setting is mode A)
Remote controller side
•
Indoor unit side
•
SERVICE FUNCTION EXPLANATION
Designated
Timer mode
temperature
26°C
CONTINUOUS
23°C
CONTINUOUS
: Have "J1" on the PC board short-circuited by soldering.
: Cut "R13" on the PC board.
Air flow
AUTOMATIC
AUTOMATIC
– 5 –
Beep
Twice beep
J1
J1
Soldering