(4)
Service clearance area
The service clearance area, or the sides which must allow access to the IDD for installation or
maintenance, is shown in Figures 4.9.
[Surface P]
• Cable connection
(5)
External magnetic field
The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence
of the external magnetic field.
(6)
Leak magnetic flux
The IDD uses a high performance magnet to achieve a high speed seek. Therefore, a leak
magnetic flux at surface of the IDD is large. Mount the IDD so that the leak magnetic flux does
not affect to near equipment.
(7)
Others
A hole or screw portion as shown in Figure 4.10 is used for adjusting air pressure balance between
inside and outside the DE. Do not fill with a seal or label.
Seals on the DE prevent the DE inside from the dust. Do not damage or peel off labels.
[Surface Q]
• Hole for mounting screw
Figure 4.9
Service clearance area
C141-E103-01EN
[Surface P']
• Setting terminal
• External operator panel connector
• Spindle sync connector
[Surface R]
• Hole for mounting screw
4 - 9