7.4 Outdoor fan motor windings resistance(@20℃).
Motor model
Winding 1 (Main)
Winding 2 (Sub)
8. Troubleshooting
For all heat pump model
Over current protection of the compressor occurs 4 times
Indoor fan speed has been out of control for over 1 minute
No over-zero signal
Temp. sensor on indoor evaporator is open circuit or short
circuit
Indoor room temp. sensor is open circuit or short circuit
EEROM error
r Extinguish
☆ Flash at 5Hz
Electronic function
9.
9.1 Electric Control working environment
9.1.1
Input voltage: 175~253V
9.1.2
Input power frequency:50Hz
9.1.3
Ambient temperature: -7°C~+43°C
9.1.4
Indoor fan normal working amp is less than 1A,
9.1.5
Outdoor fan. Normal working amp is less than 1.5A
9.1.6
Four-way valve normal working amp is less than 1A.
9.1.7
Swing motor: DC12V.
9.1.8
Compressor: single-phase power supply. Its normal working amp is less than 15A
9.2 Proper symbols and their meanings:
TA: Indoor ambient temperature
TE: Indoor evaporator temperature
TS: Setting temperature through the remote controller
I
: Self-protection amp of compressor, continue three seconds until turns off the compressor.
3sec
I
: Self-protection amp of compressor, continue five minutes until turns off the compressor.
5MIN
I
: Self-protection amp of outdoor fan/indoor fans when they change from higher wind to lower
FAN
wind.
I
: Amp self-protection return value
RESTORE
TH
: High wind, defrosting temperature difference
DEFROST
TM
: Middle wind, defrosting temperature difference
DEFROST
TL
: Low wind, defrosting temperature difference
DEFROST
TE1: Anti-cold wind, from Fan Off to Breeze temperature
TE2: Anti-cold wind, from Breeze to Setting Fan Speed temperature
TE3: Anti-cold wind, from Setting Fan Speed to Breeze temperature
Failure phenomenon
YDK25-6C
170
195
Operation lamp
14
YDK53-6K
73±8%
134±8%Ω
Timer lamp
☆
X
X
☆
☆
☆
X
X
X
☆
On
☆
Defrosting lamp
☆
☆
☆
☆
X
X