Specifications
Model No.
COMPUTER IN
1 /COMPONENT
IN
COMPUTER IN 2
/MONITOR OUT
Termi-
nals
VIDEO IN
S-VIDEO IN
HDMI IN
AUDIO IN
VARIABLE AU-
DIO OUT
SERIAL IN
LAN
Power cable length
Cabinet
Dimensions
Weight
Operating environment
Power supply
Operating range
Remote
control
Weight
Dimensions
*4: This is an average value. It may differ depending on individual product.
*5: If [Lamp power] is set to [Normal] and the operating environment temperature exceeds 35°C(95 °F),
[Lamp power] may be changed to [Eco] automatically.
• The part numbers of accessories and separately sold components are subject to change without notice.
PT-VW430U / E / EA
1 (D-sub 15 pin female)
[RGB signal]
0.7 V [p-p] 75 Ω (When G-SYNC: 1.0 [p-p] 75 Ω
HD/SYNC TTL high impedance, automatic positive/negative po-
larity compatible
VD TTL high impedance, automatic positive/negative polarity
compatible
[YP
P
signal]
Y: 1.0 V [p-p] including synchronization signal, P
B
R
75 Ω
[RGB signal]
0.7 V [p-p] 75 Ω (When G-SYNC: 1.0 [p-p] 75 Ω
HD/SYNC TTL high impedance, automatic positive/negative po-
larity compatible
VD TTL high impedance, automatic positive/negative polarity
compatible
1 (Mini DIN 4 pin, Y 1.0 V [p-p], C 0.286 V [p-p] 75 Ω, S1 signal compatible)
1 (HDMI 19 pin, HDCP and Deep color compatible)
2 (M3 stereo mini jack, 0.5 V [rms], input impedance 22 kΩ and more)
1 (RCA pin jack x 2 (L-R), 0.5 V [rms], input impedance 22 kΩ and more)
1 (M3 stereo mini jack, stereo monitor output compatible,
0 V [rms] to 2.0 V [rms] valuable, output impedance 2.2 kΩ and less)
1 (D-sub 9 pin, RS-232C compliant, for computer control use
1 (for RJ-45 network connection, PJLink compatible,)
Height: 107 mm (4.21") (when front adjustable feet shortened)
Depth: 305 mm (12.01") (excluding protractions)
Operating environment temperature
0 °C (32 °F) to 40 °C (104 °F) (Elevation: below 1 200 m; [Fan control]: [Off])
0 °C (32 °F) to 30 °C (86 °F) (Elevation: 1 200 m ~ 2 000m; [Fan control]: [On1])
0 °C (32 °F) to 30 °C (86 °F) (Elevation: 2 000 m ~ 2 700m; [Fan control]: [On2])
Operating environment humidity: 20 % to 80 % (no condensation)
DC 3 V (battery (AAA/R03
Approx. 7 m (275.6") (when operated directly in front of receptor)
67 g (2.36 ozs.) (including batteries)
Width : 52 mm (2.05"), Length : 110 mm (4.33"), Height : 18 mm (0.71")
-6-
PT-VX500U / E / EA
1 (RCA pin jack 1.0 V [p-p] 75 Ω)
2.0 m(78 3/4")
Molded plastic
Width: 379 mm (14.92")
Approx.4.8 kg(10.58 lbs.)
* 5:
or AAA/LR03 Type ) x 2
P
: 0.7 V [p-p]
B
R
* 4
)