LG LMX21981** /01 Service Manual page 39

Table of Contents

Advertisement

8-3 RESISTANCE SPECIFICATION OF SENSOR
TEMPERATURE
- 20 ˚C
- 15 ˚C
- 10 ˚C
- 5 ˚C
0 ˚C
+ 5 ˚C
+ 10 ˚C
+ 15 ˚C
+ 20 ˚C
+ 25 ˚C
+ 30 ˚C
+ 40 ˚C
+ 50 ˚C
• The resistance of the SENSOR has a ±5% tolerance.
• Measure the resistance of the SENSOR after leaving it for over 3 minutes in the measuring temperature.
This delay is necessary due to sensor response speed.
• Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
RESISTANCE OF FREEZER/ICING
SENSOR
22.3 KΩ
16.9 KΩ
13.0 KΩ
10.1 KΩ
7.8 KΩ
6.2 KΩ
4.9 KΩ
3.9 KΩ
3.1 KΩ
2.5 KΩ
2.0 KΩ
1.4 KΩ
0.8 KΩ
- 38 -
RESISTANCE OF REFRIGERATOR &
DEFROST SENSOR & ROOM SENSOR
77 KΩ
60 KΩ
47.3 KΩ
38.4 KΩ
30 KΩ
24.1 KΩ
19.5 KΩ
15.9 KΩ
13 KΩ
11 KΩ
8.9 KΩ
6.2 KΩ
4.3 KΩ

Advertisement