    INDEX • Index • Specification • Safety Information • Parts • Installation of the Exhaust Pipe • Mounting of the Exhaust Pipe • Installation of the Carbon Filter • Operation • Setting the Fan Speed • Setting the Timer • Regulating the Airflow •...
  • Page 3: Specification

    SPECIFICATION Model AC9410-EH AC12410-EH 1Ph, 220- 1Ph, 220- Power Supply (Ph, V~Hz) 240V, 50Hz 240V, 50Hz Capacity (BTU/hr) 8,000 10,000 Power Consumption (W) 1,030 Operating Current (A) Cooling EER (BTU/w.h) 2.88 2.75 Working Temperature ( 18 - 32 18 - 32 Capacity (BTU/hr) 8,000 10,000...
  • Page 4: Safety Information

    SAFETY INFORMATION General Safety • Only use in an upright position on a flat, level surface • Always use the carry handles to move the product and NOT the electricity cable • Do not place objects on the unit or restrict the air inlet/outlet •...
  • Page 5: Front

    PARTS Front Back Control Panel Air filter Air outlet Air inlet Carrying handle Exhaust air outlet Caster Cord storage Drainage point Accessories 10. Inward adaptor - inserts over hose and into back of the air conditioner 11. Outward adaptor - inserts over hose and into foam strip (supplied) 12.
  • Page 6: Installation Of The Exhaust Pipe

    INSTALLATION Installation of the exhaust pipe This unit is a portable air conditioner, which may be easily moved from room to room, using the following methods 1. Using the foam strips Foam strips • Open a suitable window • Place the unit at least 50cm away from the window •...
  • Page 7: Mounting Of The Exhaust Pipe

    INSTALLATION Mounting of the exhaust pipe • Using only the hose provided, clip the exhaust hose and unit adaptor to the back of the air conditioner • Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down •...
  • Page 8: Installation Of The Carbon Filter

    INSTALLATION Installation of the carbon filter Slide up and remove the filter frame from the unit Separate the filter guard from the filter frame Remove the active carbon filter from its plastic bag Insert the active carbon filter into the filter frame Fix the filter by reassembling the filter guard onto the filter frame Carefully slide the filter frame back inside the unit...
  • Page 9: Operation

    OPERATION Control panel Set Temperature indicator Room Temperature indicator Low ventilation indicator High ventilation indicator Automatic function indicator Cooling mode indicator Fan function indicator Heating function indicator Timer operation indicator 14. Mode (function) button 10. Compressor operation 15. Timer button indicator 16.
  • Page 10: Setting The Fan Speed

    OPERATION Setting fan speed Press SPEED button to choose the required fan speed. The indicator hi or lo will light when a setting is chosen If the unit is in AUTO function it will choose the fan speed automatically, according to the ambient temperature (the speed switch is invalid when the unit is in AUTO function) Setting timer 1.
  • Page 11: Drainage

    DRAINAGE During the process of cooling, some water will be extracted from the air into the unit. If the reservoir is full, both the compressor and the motor will stop. When this occurs, the ‘comp’ indicator will flash For the unit to function again, the water must be drained in one of the following ways: Turn off the air conditioner 2.
  • Page 12 DRAINAGE Please note The drain must be at or below the outlet level 2. Flashing ‘comp’ indicator will not function with this method of drainage 3. If you want to extend the water tube, you can connect it with another tube (OD: 18mm) WARNING Whilst using the heating function, please note:...
  • Page 13: Maintenance

    MAINTENANCE WARNING – Always unplug the air conditioner from the mains before cleaning To maximize the efficiency of the air conditioner, clean regularly Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths or other cleansing solutions as these could damage the unit Cleaning the filter...
  • Page 14: Fault Check List

    FAULT CHECK LIST The air conditioner will not run: Is the air conditioner plugged in? Is there a power failure? Is the ‘comp’ indicator flashing? Is the ambient temperature below the set temperature? The machine seems to do little: Is there direct sunshine? (Please close curtains) Are too many windows or doors open? Are there too many people in the room?