This projector provides the following circuit protections to operate in safety. If the abnormality occurs inside the pro-
jector, it will automatically turn off by operating one of the following protection circuits.

Thermal fuse (SW902)

There is a thermal fuse (SW902) inside of the projector to detect the
internal temperature rising abnormally. When the internal tempera-
ture around lamp reaches near 113˚C, the thermal fuse will open to
cut off the power supply to the lamp power circuit.
If the thermal fuse opens, the projector cannot turn on. Thermal
fuse replacement is required.

Lamp cover switch (SW901)

The lamp cover switch (SW901) cuts off the drive signal to the lamp
circuit when the lamp cover is removed or not closed completely.
After opening the lamp cover for replacing the lamp assy, place the
lamp cover correctly otherwise the projector can not turn on.

Fuse (F601)

A fuse is located inside of the projector. When the POWER indica-
tor is not lighting, the fuse may be opened. Check the fuse as fol-
lowing steps.
The fuse should be used with the following type;
Fuse Part No.: 323 021 7804
TYPE T6.3AH 250V FUSE
LITTEL FUSE INC. TYPE 21506.3
or
Fuse Part No, : 423 034 4101
TYPE T6.3AH 250V FUSE
Hollyland Co, Ltd. TYPE 50CT063H
How to replace the fuse
1. The fuse is placed on the filter board. Remove the cabinet top
following the "Mechanical Disassembly" .
2. Take the fuse off from the fuse holder, and replace the new one
with the specified type.