Using The Pump - Soleus Air SG-DEH-70EP-2 Operating Instructions Manual

Portable dehumidifier with external pump
Table of Contents

Advertisement

USING THE PUMP

NOTE: Make sure the drain hose is lower than the horizontal plane of the drain on
the dehumidifier as seen in the illustration below. Drain hose should be as short as
possible and all kinks in the drain hose should be eliminated for proper pump opera-
tion.
3ft. Dehumidifier Drain Hose
NOTE: If you need to cut the dehumidifier drain hose, only cut on the flat end of the
hose. Do not cut the angled end as it is designed for insertion into the pump.
CUT
1.
Remove flat end of the hose by squeezing the large clamp and pulling it to-
ward you.
2.
Remove hose from drainage joint and cut hose to appropriate length.
3.
Once cut is completed, refer to installing the Drain Hose to re-install dehu-
midifier drain hose.
USING THE DRAIN PUMP
1.
Plug into grounded electrical outlet.
2.
Place the other end of the pump hose where you would like to empty the wa-
ter (floor drain, water container or through a basement window). The pump
will automatically start and begin pumping the water that drains into it. Check
hose for kinks or other obstructions.
3.
Before and after each use, check hose connections to make sure they are
properly secured.
(FIG. 17)
DO NOT CUT
12
INSTALLING THE GRAVITY DRAIN HOSE
4:
Step
Insert the drain hose onto the drainage joint so that it is fully seated. (Fig. 9)
Step 5: Secure hose by pushing large hose clamp towards the drainage joint. (Fig.
10)
Step 6: Place bucket in the dehumidifier for operation. (Fig. 11)
(FIG. 9)
(FIG. 10)
(FIG. 11)
9