TROUBLESHOOTING

Problem
Possible Causes
Dehumidifier does not
The dehumidifier is un-
start.
plugged.
The fuse is blown / circuit
breaker is tripped.
Dehumidifier has reached
the user set humidity level
or the bucket is full.
Bucket is not in the proper
position.
Power Failure.
Dehumidifier is not oper-
Not enough time
ating as
for unit to remove moisture.
Intended.
Airflow is restricted.
Dirty filter.
The user set Humidity Level
may not be set low enough.
Doors and windows may
not be closed tightly.
Water is not draining
through drain hose
Room temperature is too
low.
Filter Indicator is lit.
Filter needs to be cleaned
every 250 hours of use.
Solutions
Make sure the dehumidifier's plug is pushed com-
pletely into the outlet.
Check the house fuse / circuit breaker box and
replace fuse or reset breaker.
The dehumidifier automatically turns off when either
condition occurs. Change to a lower setting or
empty the water bucket and replace properly.
The bucket must be in place and securely seated for
the dehumidifier to operate.
There is a protective time delay of 3 minutes to
prevent tripping of the compressor overload. For this
reason, the unit will not start normal dehumidifica-
tion for 3 min. after it is powered back on.
allowed
When first installed, allow at least 24 hours to
achieve the desired humidity level.
Make sure there are no curtains, blinds, or furniture
blocking the side or back of the dehumidifier.
See the Cleaning The Air Filter section
To reduce moisture, press the down arrow button to
lower the percent humidity desired in the room, or
set the dehumidifier to CO for continuous operation.
Check that all doors, windows, and other openings
are securely closed.
Make sure the drain is placed below the drain con-
nector nozzle to allow gravity to drain the water
(Refer to Gravity Drain Hose section in this manual).
Moisture removal is best at higher room tempera-
tures. Lower room temperatures will reduce the
moisture removal rate. This model is designed to
operate at temperatures above 41°F.
Once filter has been cleaned, press the FILTER but-
ton for 3 seconds to turn the filter indicator off.
14

WATER DISPOSING OPTIONS

OPTION 1: EMPTYING MANUALLY
1. Pull out the bucket, grasping the side handles. (Fig. 1)
2. Carry the bucket by grasping the front corner of the bucket with one hand and the back of
the bucket with the other hand( Fig. 2)
3. Empty the bucket and replace the bucket in the dehumidifier. (Fig. 3)
NOTE: Dehumidifier will not work and settings can not be changed when the BUCKET FULL
indicator light is flashing or without the bucket properly installed.
DO NOT REMOVE THE STYROFOAM IN THE BUCKET
This dehumidifier is equipped with a reliable Styrofoam float system. The Styrofoam
located inside the float in the bucket is essential to the bucket full system working
properly. Do not remove the Styrofoam from the float.
(Fig. 1)
(Fig. 3)
(Fig. 2)